seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Instructions for general repairs > < Air conditioning equipment: removing and installing
Safety measures
Safety measures
The following safety measures are to be followed for this refrigerant (additional regulations may apply in other countries).
If during repair work, the coolant circuit must be opened, first empty the circuit → Chapter. When doing so, avoid contact with liquid or gas coolant. If in spite of taking all safety precautions coolant leaks, the combination of coolant/air should not be inhaled.
In this situation, turn on any suction system and protect hands with gloves and the eyes with protective glasses.
Reason
The intensive action of the refrigerant on unprotected parts of the body may lead to freezing of those parts.
  Caution
Always keep an eye wash flask close to hand.
If the refrigerant comes into contact with the eyes, immediately begin thorough rinsing of the eyes for 15 minutes.
Then, apply eye drops and seek medical assistance even if the eyes do not cause any pain.
The medical assistance must be given all of the details of the refrigerant causing the problem.
If, despite taking the safety precautions, any part of the body comes into contact with the refrigerant, also rinse thoroughly and immediately with cold water for about 15 minutes minimum.
Even that the refrigerant is not flammable, in any enclosed space where work is carried out with the refrigerant there must be no smoking and no welding or soldering work.
Reason
In high temperatures from flames or hot bodies the coolant gas breaks down chemically. Inhalation of the broken down products may cause irritating coughs or dizziness.
   

Instructions for general repairs > < Air conditioning equipment: removing and installing