| Pinch off both engine coolant hoses to the climate control heat exchanger e.g. using the clamp -U-30042-. |
l
| Do the measurement values in the two indication fields referring to the Servomotor for the left hand side temperature flap -V158-, Servomotor for the right hand side temperature flap. -V159-: (Climatic: Servomotor for the temperature flap -V68-) only differ by less than 3 °C from the measurement value of the Air temperature sender, evaporator output -G263-? → Vehicle diagnosis, testing and information system VAS 5051 |
|
↓ yes ↓
| ↓ No ↓
|
–
| Remove the pressure tool -U-30042- from the two coolant hoses. | ↓ | –
| Check correct installation of sender with measured value deviation, as well as checking electrical connections for contact resistance. |
|
–
| Check the activation and the operation of the Servomotor for the left hand side temperature flap -V158-, Servomotor for the right hand side temperature flap. -V159-: (Climatic: Servomotor for the temperature flap -V68- → Chapter and → Chapter | ↓ Continued on the following page | –
| Eliminate the cause of the faulty measurement, replace the faulty sender. |
|