| Pinch off both coolant tubes to heating system heat exchanger e.g. using the clamp -U-30042-. |
l
| If the measurement values deviate in both display fields of the left temperature flap servomotor -V158-, the right temperature flap servomotor -V159- (Climatic: Temperature flap servomotor -V68-) is only less than 3 °C of the measurement value of the evaporator outlet temperature sender -G263-? → Vehicle diagnostic, testing and information system VAS 5051 |
|
↓ yes ↓
| ↓ no ↓
|
–
| Remove the pressure clip -U-30042- | ↓ | –
| Check correct installation of sender with measured value deviation, as well as checking electrical connections for contact resistance. |
|
–
| Check the activation and operation of the left temperature flap servomotor -V158- and the right temperature flap servomotor -V159- (Climatic: Temperature flap servomotor -V68-) → Chapter and → Chapter. | ↓ Continued on the following page | –
| Eliminate the cause of the faulty measurement, replace the faulty sender. |
|