Leon Mk1
Display groups assembly overview |
Display group 000 -Decimal values- | ||||||||||||||||||
Checking conditions
| ||||||||||||||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | ← Display zones | Specification | Corresponds to | ||||||
Engine speed | 71…67 | 825…875 rpm | ||||||||||||||||
Injection period | 4…10 | 2,25…5,00 ms | ||||||||||||||||
Throttle valve angle | 23…42 | 10…18 ∠° | ||||||||||||||||
Do not consider | — | — | ||||||||||||||||
Do not consider | — | — | ||||||||||||||||
Lambda probe signal | ||||||||||||||||||
minimum | 0…20 | 0…0,1 V | ||||||||||||||||
maximum | 123…195 | 0,6…0,95 V | ||||||||||||||||
Intake manifold pressure | 45…84 | 300…480 mbr | ||||||||||||||||
Coolant temperature | 37…19 | 80…105 °C | ||||||||||||||||
Battery voltage | 187…226 | 12,0…14,5 V | ||||||||||||||||
Intake air temperature | 156…44 | 15…70 °C |
Display zones | ||||
1 | 2 | 3 | 4 | |
Display group 01 | ||||
Display | xxxx rpm | xx,x °C | x,x V | xxxxxxxx |
Indicated | Engine speed | Coolant temperature | Lambda probe voltage | Adjustment conditions → Note |
Specifications → Note | 825…875 → Note | 80…105 | 0,1…0,95 fluctuating | 00000000 |
Display group 02 | ||||
Display | xxxx rpm | xx,xx ms | xx,x V | xx,x °C |
Indicated | Engine speed | Injection period | Battery voltage | Intake air temperature |
Specifications → Note | 825…875 → Note | 2,25…5,00 | 12,0…14,5 V | 15…70 |
1) | Specifications should be reached when: engine running at idling speed; coolant temperature is a minimum of 80 °C; the electrical consumers are disconnected |
3) | Significance of 8 digit number block codes → Chapter |
Display zones | ||||
1 | 2 | 3 | 4 | |
Display group 03 | ||||
Display | xxxx/min | xxx % | xx ∠° | xx,x % |
Indicated | Engine speed | Intake manifold pressure | Throttle valve angle | Opening the throttle via the positioner |
Specifications → Note | 825…875 → Note | 45…84 | 9…18 | 17…29 |
Display group 04 | ||||
Display | xxxx/min | xxx % | xxx | xxxxxxxx |
Indicated | Engine speed | Intake manifold pressure | Road speed | Operating mode → Note |
Specifications → Note | 825…875 → Note | 45…84 | 255 | 01000000 |
4) | Specifications should be reached when: engine running at idling speed; coolant temperature is a minimum of 80 °C; the electrical consumers are disconnected |
6) | Significance of 8 digit number block codes → Chapter |
Display zones | ||||
1 | 2 | 3 | 4 | |
Display group 05 | ||||
Display | xxxx/min | xxx % | ||
Indicated | Engine speed | Activated charcoal filter solenoid valve 1 duty cycle | — | — |
Specifications → Note | 825…875 → Note | 6…19 | — | — |
7) | Specifications should be reached when: engine running at idling speed; coolant temperature is a minimum of 80 °C; the electrical consumers are disconnected |