seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Display groups assembly overview > < Safety precautions
Read measured value block
Read measured value block
Special tools and workshop equipment required
   
t  Fault reader -V.A.G 1551- or vehicle system tester -V.A.G 1552- with cable -V.A.G 1551/3B-
Checking conditions
l  Coolant temperature must be at least 80 °C → Anchor, display zone 2
l  All electric consumers, e.g.: lights and rear window heater must be switched off.
l  If the vehicle is equipped with air conditioning, this must be switched off.
l  There should be no faults registered in the memory → Chapter, Fault memory: interrogate.
Work sequence
–  Connect fault reader -V.A.G 1551- (-V.A.G 1552-). Start engine and enter “Address code” 01 to select engine control unit. (Fault reader: Connecting and selecting the engine control unit → Chapter.)
  W00-0459
Indicated on the display:
–  Press keys 0 and 8 for the function “Read measured value block” and confirm entry with the Q key.
 
Rapid data transfer                 HELP
Select function XX                      
Indicated on the display:
–  Select required display group number.
  Note!
Display group number 1 is merely an example to illustrate the sequence.
–  Press keys 0, 0 and 1 for “Display group number 1” and confirm entry with the Q key.
 
Read measured value block           HELP
Input display group number XXX          
Indicated on the display:
(1…4 = display zones)
  Note!
To change to another display group, proceed as follows:
 
Read measured value block 1           ->
         1         2         3         4
Display group-V.A.G 1551--V.A.G 1552-
higherpress key 3press key
lowerpress key 1press key
skippress key Cpress key C

–  If the specifications in all display zones are obtained, press the key.
   
Indicated on the display:
–  Press keys 0 and 6 for the “End data transfer” function and confirm input with the Q key.
  Note!
Measured value blocks which are not described in this chapter are currently only intended for research and development and production. The values displayed are not relevant for service department fault finding.
 
Rapid data transfer                 HELP
Select function XX                      

Display groups assembly overview > < Safety precautions