seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Charge air system with turbocharger > < Removing and installing fuel delivery unit
Checking overrun shut-off valve
Checking overrun shut-off valve
Special tools and workshop equipment required
   
t  Hand vacuum pump -SAT 1390-
Test conditions
l  Reduced performance or load change judders
l  Turbocharger noisy when throttle valve is closed
Test sequence
  Note!
The overrun shut-off valve is located in front of the turbocharger. It is opened by vacuum pressure during the overrun phase and at idling speed.
  W00-2716
–  Connect hand vacuum pump -SAT 1390- to vacuum connection on overrun shut-off valve.
–  Operate hand vacuum pump overrun valve must open -arrow-.
–  Operate vent valve on hand vacuum pump overrun valve must close -arrow-.
Overrun valve does not open or close, renew valve.
  Note!
The overrun shut-off valve connections must be secured with spring-type clips.
  E21-0008

Charge air system with turbocharger > < Removing and installing fuel delivery unit