| Remove the ventilation pipe -1-. To do so, press the release tabs. |
–
| Then connect the manual vacuum pump -VAS 6213- using the adaptor set -VAG 1318/17- to the line which goes to the activated carbon system. |
–
| Operate the manual vacuum pump -VAS 6213- a few times. Vacuum must not build up. |
–
| Check if the ventilation hose of the → Itemactivated carbon filter is dirty and clean it, if necessary. |
If a vacuum does not build up: |
–
| Temporarily seal ventilation → Itemhose and operate vacuum pump again several times. A vacuum must build up. |
If a vacuum does not build up: |
–
| Renew active carbon filter. |
|
|
|