t
| Manual pump -SAT 1390-, see equivalent → Anchor |
Note The depression actuator for the switching valve is accessed from below. |
–
| Remove the depression flexible hose from the depression box. |
–
| Couple the manual vacuum pump to the depression box. |
–
| Operate hand vacuum pump. |
l
| The switching link for the exhaust gas recirculation radiator should move -arrows-. |
If the link does not move, or does it at jolts: |
t
| The depression box is faulty. |
t
| The switching valve for the exhaust gas recirculation radiator has heavy movement. |
|
|
|