Battery monitoring control unit J367
- Make
- Skoda
- Model
- Citigo
- Year
- NF, 2012 on
- Section
- Electrical System › Battery monitoring control unit J367
Battery monitoring control unit J367
The control unit is located directly at the negative connection terminal of the battery earth cable.
It transmits information on whether the battery has enough electric power for the operation of the start-stop system.
It is connected to the data bus diagnostic interface J533 (Gateway) via the LIN data bus.
In the event of a failure, an entry is made in the fault memory. The start-stop system is switched off.
After replacing the battery monitoring control unit J367, perform the adaptation (coding) with Vehicle diagnostic tester.
Parts & tools for this job For 2012 Skoda Citigo
- TOOLBattery testerSearch: car battery tester
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBattery terminal cleanerSearch: battery terminal cleaner