| Test the specified values for the electronic throttle potentiometer voltages. |
Note The engine control unit converts the voltage values of the accelerator pedal position sender in percentage (in relation to 5 Volts). 5 Volts power supply correspond to 100%. |
–
| Observe display fields 3 and 4. |
–
| Slowly press the accelerator pedal fully down. |
The percentage indication in display field 3 must rise gradually. The tolerance range 6…97 % is not fully used up. |
The percentage indication in display field 4 must rise gradually. The tolerance range 3…50 % is not fully used up. |
Note The value displayed in display field 3 must always be approximately double the value in display field 4. |
If the display does not occur as described: |
–
| Test the voltage supply and the wiring of the throttle valve control unit -J338- → Chapter. |
|
|
Reading measured value block 62 -> | 15,0 % 75,0 % 15,0 % 7,0 % |
|