| Unplug the 3 pin plug connection -1-. |
–
| Unscrew high pressure sender -G65--2-. |
Installation is performed in the reverse order, pay attention to the following points: |
–
| Replace O-Ring (10.80 mm; 1.82 mm) -3-, moisten with refrigerant oil and carefully insert in the connection slot -4-. |
Note The refrigerant circuit remains closed, connection to valve. |
Check for proper operation |
The function of the high pressure sender -G65- can be checked via self-diagnosis of the air conditioning system control unit -J301- → Chapter. |
|
|
|