skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Inspecting the pressure relief valve on the compressor > < Removing and installing, inspecting high pressure sender G65
Removing and installing the expansion valve
Removing and installing the expansion valve
Must only be carried out in a specialist service centre which has suitably trained personnel and is fitted out for working on the refrigerant circuit!
Removing
–  Drain the refrigerant circuit with the aid of the A/C service station.
–  Removing refrigerant lines from the expansion valve → Fig..
   
–  Release screws -4-.
   Tightening torque: 5 Nm
–  Remove expansion valve -3-.
  Note
t  Shut off open connections on the evaporator.
t  Replace O-ring -2- (11.10 mm; 1.78 mm) and -5- (17.17 mm; 1.78 mm), moisten with refrigerant oil and mount on the refrigerant lines of the evaporator.
t  The expansion valve must be correctly positioned in the heat-protection insulation -1-.
Install
Installation is carried out in the reverse order. Pay attention to the following:
–  Replacing dessicator insert → Chapter.
–  Fill the refrigerant circuit with the aid of the A/C service station.
  S87-0151