Fabia Mk1
|
|
Switch on measuring range: Resistance measurement (200 Ω) | |||||||||||||
Plug to the solenoid valves and to the gearbox oil temperature sender -G93- | Adapter cable -V.A.G 1598/18- bushes | Specification | Measures for deviations from nominal value | ||||||||||
1 | 48 | less than 1.5 Ω |
| ||||||||||
2 | 49 | less than 1.5 Ω | |||||||||||
3 | 26 | less than 1.5 Ω | |||||||||||
4 | 66 | less than 1.5 Ω | |||||||||||
5 | 25 | less than 1.5 Ω | |||||||||||
6 | 33 | less than 1.5 Ω | |||||||||||
7 | 34 | less than 1.5 Ω | |||||||||||
8 | 50 | less than 1.5 Ω |
Note
If this test of the wiring does not show any unauthorised deviations, replace the gearbox oil temperaturesender -G93-,the wiring in the slide valve body or the solenoid valves → Chapter. |