| Remove the ventilation line -1- from the activated charcoal filter to the activated charcoal filter system solenoid valve 1 -N80--2-. |
–
| Connect hand vacuum pump -VAS 6213- to vent line -1- as shown. |
–
| Operate the hand vacuum pump several times. No vacuum should build up. |
–
| Check the ventilation opening below the cover -4- on the activated charcoal filter -3- for dirt, clean as required. |
–
| Remove the cover -4-, shut off the ventilation opening on the activated charcoal filter and once again operate the hand vacuum pump several times. A vacuum should build up. |
–
| Replace activated charcoal filter. |
|
|
|