| Position clamping lever -MP1-203 (3297)-, secure by inserting the pin -arrow- and and press AC generator in -direction of arrow-. |
–
| Remove the released ribbed V-belt from the AC generator - belt pulley. |
Installing the V-ribbed belt |
–
| Installation is carried out in the reverse order. |
–
| Inspect the V-ribbed belt: |
–
| Check smooth operation of belt pulley and tensioning pulley. |
Note t
| Before fitting the V-ribbed belt make sure that all assemblies (generator and AC compressor) are securely mounted. |
t
| Pay attention to the correct position and rotation direction of the V-ribbed belt in the belt pulley when installing it. |
–
| Push AC generator down with clamping lever -MP1-203 (3297)-. |
–
| Lay the V-ribbed belt on the crankshaft belt pulley. |
–
| Push AC generator down and fit on belt. |
Once the AC generator is released the belt is tensioned to nominal dimension. |
–
| After fitting the ribbed V-belt, crank the engine several times with the starter (about 10 turns) once the AC generator is released. |
Note Before tightening the screws for the AC generator, do not move it and do not push the V-ribbed belt down. |
–
| First tighten the bottom and then the top screw for AC generator to 23 Nm. |
|
|
|