Draining and filling up coolant
Draining and filling up coolant
(Fabia II, Roomster, Rapid)
Special tools and workshop equipment required
t  Catch pan, e.g. -VAS 6208-
t  Pliers for spring strap clamps
t  Refractometer -T10007- or -T10007A-
Draining
  Note
Collect drained coolant in a clean container for proper disposal or reuse.
  WARNING
Hot steam or hot coolant may escape when the compensation bottle is opened. Cover the cap with a cloth and open carefully.
–  Open the cap of the coolant expansion reservoir.
–  Remove the sound dampening system → Body Work; Rep. gr.50.
–  Place a catch pan under the engine.
   
–  Remove the coolant hoses -2- at the coolant recirculation pump 2 -V178--3-.
–  Remove the left charge air hose.
  WARNING
Shut off the opening of the charge air cooler, e.g. with a clean foam piece, so that no coolant can penetrate.
  N19-10330
–  Remove the coolant hose from the radiator; to do so loosen the retaining clip -arrow-.
  N19-10340
–  Remove the coolant hose on the engine oil cooler -arrow- and drain residual coolant.
Filling up
  Note
Replace O-rings.
  N19-10286
–  Connect coolant hose at bottom of radiator -arrow-.
–  Install left charge air hose.
  N19-10340
–  Connect the coolant hoses -2- at the coolant recirculation pump 2 -V178-.
  N19-10330
–  Connect the coolant hose on the engine oil cooler -arrow-.
Select the appropriate coolant additive from the Electronic Catalogue of Original Parts Škoda or from the list of allowed coolant additives:
t  → BookletFabia II.
t  → BookletRoomster.
t  → BookletRapid.
–  In a clean reservoir mix water and coolant additive in the specified mixing ratio:
t  → BookletFabia II.
t  → BookletRoomster.
t  → BookletRapid.
  N19-10286
–  Top up coolant in the expansion reservoir, until the „max. marking“ of the coolant level is reached.
–  Switch off the heating, and if present, the air conditioning system.
–  Start engine, run for not more than 3 minutes at approx. 2000 rpm and while doing so continuously top up coolant in the expansion reservoir.
–  Tighten cap at expansion reservoir.
–  Run engine until radiator fan starts.
  WARNING
Hot steam may escape when the compensation bottle is opened.
t  Wear safety goggles and safety clothing, in order to avoid eye injuries and scalding.
t  Cover the cap with a cloth and open carefully.
–  Check the level of coolant when the expansion reservoir is closed and top up if necessary when the engine is cooled down.
l  When engine is at operating temperature the coolant level must be at the „max. marking“, when engine is cold between the „min. marking“ and the „max. marking“.
  S19-0077

Remove and install coolant recirculation pump 2V178 > < Connection diagram for coolant hoses