Test steps 21 - 28
- Make
- Skoda
- Model
- Octavia Mk1
- Section
- Brake systems › Test steps 21 - 28
‹ Prev Test steps 1 - 20Next › Electric/electronic components and fitting locations ABS/EDL/ESP Mark 20
ABS, ADR, TCS, EDL, ESPTest steps 21 - 28
Test steps 21 - 28
| Switch on measuring range: resistance measurement (200 Ω)/(20 MΩ) | |||||
|---|---|---|---|---|---|
| Test step | V.A.G 1598 A bushes | Test covers | Test conditions additional works | Specified value | Measures for deviations from nominal value |
| 21 | - | Cables for yaw rate sender G202 | Ignition off Measuring range 200 Ω set Pull out the multi-pin connector T47a from the ABS control unit J104.Connect test box V.A.G 1598 A with adapter V.A.G 1598/33 Disconnect the plug connection T3m from the yaw rate sender G202 | ||
| Check the following line connections for an open circuit: | Test wiring for open circuit.Repair wiring according to the current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations | ||||
| Wiring of contact T3m/1 (yaw rate sender) with contact T47a/42 (control unit) Wiring of contact T3m/2 (yaw rate sender) with contact T47a/11 (control unit) Wiring of contact T3m/3 (yaw rate sender) with contact T47a/27 (control unit) | max. 1.5 Ω | ||||
| Measuring range 20 MΩ set Remove fuse S13 Check cables for short-circuit to positive or to earth | ∞Ω | ||||
| Switch on measuring range: resistance measurement (200 Ω)/(20 MΩ) | |||||
|---|---|---|---|---|---|
| Test step | V.A.G 1598 A bushes | Test covers | Test conditions additional works | Specified value | Measures for deviations from nominal value |
| 22 | - | Cables for brake pressure sender 1 G201 | Ignition off Measuring range 200 Ω set Pull out the multi-pin connector T47a from the ABS control unit J104 Connect test box V.A.G 1598 A with adapter V.A.G 1598/33 Disconnect the plug connection T30 from the brake pressure sender G201 | ||
| Check the following line connections for an open circuit:Wiring of contact T30/1 (brake pressure sender) via plug connection T14c/1 with contact T47a/28 (control unit) Wiring of contact T30/2 (brake pressure sender) via plug connection T14c/2 with contact T47a/12 (control unit) Wiring of contact T30/3 (brake pressure sender) via plug connection T14c/3 with contact T47a/43 (control unit) | max. 1.5 Ω | Test wiring for open circuit.Repair wiring according to the current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations | |||
| Measuring range 20 MΩ set Remove fuse S13 Check cables for short-circuit to positive or to earth | ∞Ω | ||||
| Switch on measuring range: resistance measurement (200 Ω)/(20 MΩ) | |||||
|---|---|---|---|---|---|
| Test step | V.A.G 1598 A bushes | Test covers | Test conditions additional works | Specified value | Measures for deviations from nominal value |
| 23 | - | Cables for brake pressure sender 2 G214 | Ignition off Measuring range 200 Ω set Pull out the multi-pin connector T47a from the ABS control unit J104 Connect test box V.A.G 1598 A with adapter V.A.G 1598/33 Disconnect the plug connection T3p from the brake pressure sender G201 | ||
| Check the following line connections for an open circuit: | Test wiring for open circuit. | ||||
| Wiring of contact T3p/1 (brake pressure sender 2) via plug connection T14c/12 with contact T47a/26 (control unit) Wiring of contact T3p/2 (brake pressure sender 2) via plug connection T14c/13 with contact T47a/10 (control unit) Wiring of contact T3p/3 (brake pressure sender) via plug connection T14c/14 with contact T47a/41 (control unit) | max. 1.5 Ω | Repair wiring according to the current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations | |||
| Measuring range 20 MΩ set Remove fuse S13 Check cables for short-circuit to positive or to earth | ∞Ω | ||||
| Switch on measuring range: resistance measurement (200 Ω)/(20 MΩ) | |||||
|---|---|---|---|---|---|
| Test step | V.A.G 1598 A bushes | Test covers | Test conditions additional works | Specified value | Measures for deviations from nominal value |
| 24 | - | Cables for solenoid coil for brake pressure N247 | Ignition off Measuring range 200 Ω set Pull out the multi-pin connector T47a from the ABS control unit J104 Connect test box V.A.G 1598 A with adapter V.A.G 1598/33 Disconnect plug connection T6x at brake servo unit Check the following line connections for an open circuit:Wiring of contact T6x/4 (solenoid coil for brake pressure N247) via plug connection T14c/7 with contact T47a/17 (ABS control unit) | ||
| Wiring of contact T6x/3 (solenoid coil for brake pressure N247) via plug connection T14c/8 with contact T47a/17 (ABS control unit J104). | max. 1.5 Ω | Test wiring for open circuit.Repair wiring according to the current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations | |||
| Measuring range 20 MΩ set Remove fuse S13 Check cables for short-circuit to positive or to earth | ∞ Ω | ||||
| Measuring range 200 Ω set Disconnect multi-pin connector T14c Check contacts (7) and (8) in the plug connection T14c to the solenoid coil for brake pressure N247 | 1.0 .. 2.0 kΩ | The brake servo unit must be replaced if the specified value is not reached Chapter “Removing and installing the brake servo unit - LHD vehicles”. | |||
| Switch on measuring range: resistance measurement (200 Ω)/(20 MΩ) | |||||
|---|---|---|---|---|---|
| Test step | V.A.G 1598 A bushes | Test covers | Test conditions additional works | Specified value | Measures for deviations from nominal value |
| 25 | - | Brake detection switch F83 | Ignition off Measuring range 200 Ω set Pull out the multi-pin connector T47a from the ABS control unit J104 Connect test box V.A.G 1598 A with adapter V.A.G 1598/33 Disconnect plug connection T6x at brake servo unit Check the following line connections for an open circuit:Wiring of contact T6x/1 (brake detection switch F83) via plug connection T14c/5 with contact T47a/13 (ABS control unit J104) | ||
| Wiring of contact T6x/2 (brake detection switch F83) via plug connection T14c/6 with contact T47a/29 (ABS control unit J104) Wiring of contact T6x/5 (brake detection switch F83) via plug connection T14c/9 with contact T47a/327 (ABS control unit J104). | max. 1.5 Ω | Test wiring for open circuit.Repair wiring according to the current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations | |||
| Measuring range 20 MΩ set Remove fuse S13 Check cables for short-circuit to positive or to earth | ∞ Ω | ||||
| Switch on measuring range: resistance measurement (200 Ω)/(20 MΩ) | |||||
|---|---|---|---|---|---|
| Test step | V.A.G 1598 A bushes | Test covers | Test conditions additional works | Specified value | Measures for deviations from nominal value |
| 26 | 19+20 | Data BUS cables | Ignition off Measuring range 200 Ω set Disconnect the multi-pin plug connections from the control units connected to a data BUS line (connection in the dash panel wiring loom A122 and A121) Connect test box V.A.G 1598 A with adapter V.A.G 1598/33 Check the following line connections for an open circuit:to the steering angle sender to the engine control unit to the automatic gearbox control unit 1) | ||
| Wiring of contact T47a/19 (control unit) via connection A121 to contact T6w/3 (steering angle sender G85) Continue via connection A121 to the connected control units Wiring of contact T47a/20 (control unit) via connection A122 to contact T6w/2 (steering angle sender G85).Continue via connection A122 to the connected control units according to current flow diagram | max. 1.5 Ω | Test wiring for open circuit.Repair wiring according to the current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations | |||
| Measuring range 20 MΩ set Remove fuse S13 Check cables for short-circuit to positive or to earth | ∞ Ω | ||||
1) Only on vehicles with automatic gearbox
| Switch on measuring range: voltage measurement (20 V =) | |||||
|---|---|---|---|---|---|
| Test step | V.A.G 1598 A bushes | Test covers | Test conditions additional works | Specified value | Measures for deviations from nominal value |
| 27 | - | Voltage supply for vehicle system tester V.A.G 1552, plug connection T16a | Ignition on | Test wiring of T16a/4 to earth.Test wiring of T16a/1 via S5.Repair wiring according to the current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations | |
| Connect the handheld multimeter, e.g. V.A.G 1526 A, with the measuring tool set V.A.G 1594 A to T16a 1) Test wiring between contact T16a/4 and contact T16a/1 | 10,0-14,5V | ||||
1) Contact assignment of the plug connection for the voltage supply and the self-diagnosis with the vehicle system tester V.A.G 1552 Chapter “Test table”
| Switch on measuring range: resistance measurement (200 Ω) | |||||
|---|---|---|---|---|---|
| Test step | V.A.G 1598 A bushes | Test covers | Test conditions additional works | Specified value | Measures for deviations from nominal value |
| 28 | - | K cable for the self-diagnosis, plug connection T16a | Ignition off | ||
| Measuring range 200 Ω set Remove fuse S13 Pull out the multi-pin connector T47a from the ABS control unit J104 Connect test box V.A.G 1598 A with adapter V.A.G 1598/33 Test wiring between contact T16a/7 and contact T47a/39 | max. 1.5 Ω | Test wiring of contact T16a/7 to contact T47a/39 Repair wiring according to the current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations | |||
| Measuring range 20 MΩ set Remove fuse S13 Check cables for short-circuit to positive or to earth | ∞Ω | Repair wiring according to the current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations | |||
‹ Prev Test steps 1 - 20Next › Electric/electronic components and fitting locations ABS/EDL/ESP Mark 20
Parts & tools for this job For Skoda Octavia
- PARTBrake padsSearch: Skoda Octavia brake pads
- TOOLBrake bleeder kitSearch: one man brake bleeder kit
- FLUIDBrake fluidSearch: brake fluid