Octavia Mk1
|
Example for inlet valve: | |||
Measured distance | 44.1 mm | ||
- | Minimum dimension | - 43.4 mm | |
= | max. permissible reworking dimension | = 0.7 mm |
Note
|
|
Example for inlet valve: | |||
Measured distance | 44.1 mm | ||
- | Minimum dimension | - 43.4 mm | |
= | max. permissible reworking dimension | = 0.7 mm |
Note
|