Note After selecting display group number 011, the idling speed is increased by the engine control unit in display block 1 to 1380...1420 rpm. |
The display in display field 2 must switch between “off” and “on” every 10 seconds. |
The following readouts must fluctuate in display fields 3 and 4: |
t
| Specification in display field 3: atmospheric pressure in mbar |
t
| Specification in display field 4: 98…100 % |
t
| Specification in display field 3: atmospheric pressure in mbar + 100...250 mbar |
t
| Specification in display field 4: 0…2 % |
Continue the test as follows: |
–
| Select function 08“read measured value block” and display group 011. |
–
| Accelerate vehicle in 2nd gear from about 1000 rpm to 3200 rpm. While doing so the accelerator pedal must be fully pressed down. |
|
|
Basic setting 11 -> | 1400 rpm OFF 982 mbar 99 % |
|