Procedure after voltage supply has been interrupted > < Testing voltage supply, terminal 30
Testing voltage supply, terminal 15
Testing voltage supply, terminal 15
For engines with identification characters AEG, APK, AQY
–  Connect test box-V.A.G 1598/22- to the wiring loom on the engine control unit → Chapter.
–  Use multimeter to measure voltage supply between sockets 1 + 2 of test box.
For engines with identification characters AZH, AZJ
–  Connect test box-V.A.G 1598/31- to the wiring loom on the engine control unit → Chapter. The control unit is not connected for this test.
–  Use multimeter to measure voltage supply between sockets 1 + 3 of test box.
Continued for all engines
–  Switch on ignition.
Specified value: min. 11.5 V
If the specified value is not reached:
–  Check cable connections to relay carrier according to the current flow diagram → Current flow diagrams and Fitting locations.
   