Test step 4
- Make
- Skoda
- Model
- Octavia Mk1
- Section
- Manual gearbox 02M, 02Y › Test step 4
Test step 4
What is tested is the function of the data BUS lines.
Switch on measuring range 2 kΩ.
Measure between the contact 7 and the contact 8 when the plug is disconnected.

Specified value: 50…70 Ω
If the specified value is not reached:
Test data BUS lines according to the current flow diagram for open circuit or short-circuit and/or proper routing. To do so, disconnect the multi-pin connectors of all control units connected to the data BUS.
Switch on measuring range 20 MΩ.
Carry out the following resistance measurements on the disconnected plug of the four-wheel drive control unit J492:
| Between contact: | Specified value | ||
|---|---|---|---|
| 7 + 8 | ∞ Ω | ||
| 7 + 1 | ∞ Ω | ||
| 8 + 1 | ∞ Ω | ||
| 7 + 2 | ∞ Ω | ||
| 8 + 2 | ∞ Ω |
In addition, test the data BUS lines for open circuit. Cable resistance: max. 1.5 Ω.
If the specified values are not reached:
Repair wiring according to current flow diagram Current flow diagrams and Fitting locations.
If the specified values are reached:
Re-connect the multi-pin connector of all the control unit and read the fault memory of all the control units connected to the data BUS and if necessary eliminate fault.