| Separate 3-pin plug connection and remove pressure switch -B- (5 Nm). |
–
| Replace -O--ring seal -A- (10.8 mm; 1.8 mm). |
Installation is performed in the reverse order, pay attention to the following points: |
Note The refrigerant circuit remains closed, connection to valve. |
Inspect proper operation: |
The high pressure sensor -G65- is an information transmitter for the radiator fan control unit -J293- and for the engine control unit. It can only be checked via self-diagnosis of the engine control unit → Engine; Rep. Gr.01 self-diagnosis. |
|
|
|