Removing and installing the refrigerant lines on the expansion valve
Removing and installing the refrigerant lines on the expansion valve
(Must only be performed in a service centre!)
–  Drain refrigerant circuit.
–  Remove heat-protection insulation -A- → Chapter.
   
–  Remove screw -B- (8 Nm) and remove refrigerant lines -C- and -D-.
Installation is performed in the reverse order, pay attention to the following points:
  Note
t  Replace both “O”-ring seals -E- (16.7 mm; 1.8 mm) and -F- (7.6 mm; 1.8 mm).
t  Shut off open refrigerant lines and expansion valve connections.
t  Fit refrigerant lines stress free.
  A87-0132