skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

2 way valve for coolant shut-off valve N147 > < Removing and installing dust pollen filter
Remove and install coolant shut-off valve of heating system
Remove and install coolant shut-off valve of heating system
Vehicles with mapped cooling
Removing
   
The coolant shut-off valve -arrow- is located in the engine compartment in the area of the heat exchanger flange.
–  Remove intake hose.
–  Reduce pressure in the coolant circuit by opening the cap on the coolant expansion reservoir.
–  Disconnect coolant hoses before and after the coolant shut-off valve with hose clamps -MP 7-602-.
–  Detach vacuum hose from the coolant shut-off valve.
–  Position collecting vessel under the shut-off valve and detach coolant hoses from the valve.
Install
Installation is carried out in the reverse order.
–  After installing, fill up with coolant according to specification → 
  S87-0174

2 way valve for coolant shut-off valve N147 > < Removing and installing dust pollen filter