Octavia Mk1
Overview of the selectable display group numbers |
Read-out on display (example) | Display group no. | Display field | Denomination | |
Reading measured value block P 0.8 V | 1 → 0 % 00000111 | 001 | 1 2 3 4 | Selector lever position Voltage throttle valve control unit Accelerator pedal value Switch positions |
Reading measured value block 0.983 A 0.985 A | 2 → 12.76 V 2.50 V | 002 | 1 2 3 4 | Current flow of the solenoid valve 6 -N93- Desired flow of the solenoid valve 6 -N93- Battery voltage Voltage at the vehicle speed sender -G68- |
Reading measured value block 0 km/h 900/min | 3 → 0 0 % | 003 | 1 2 3 4 | Speed Engine speed Gear engaged Accelerator pedal value |
Reading measured value block 1010 00 0 | 4 → P 0km/h | 004 | 1 2 3 4 | Solenoid valves Gear engaged Selector lever position Speed |
Read-out on display (example) | Display group no. | Display field | Denomination | |
Reading measured value block 45 °C 0011001 | 5 → 0 900 /rpm | 005 | 1 2 3 4 | ATF temperature Shift outputs Gear engaged Engine speed |
Reading measured value block +8 % 35 % | 6 → 41 % 60 % | 006 | 1 2 3 4 | Must not be considered at the moment Must not be considered at the moment Sportiness factor Accelerator pedal value |
Reading measured value block R 200/min | 7 → 900/rpm 0 % | 007 | 1 2 3 4 | Gear engaged Slip of the lockup clutch Engine speed Accelerator pedal value |
Reading measured value block | 8 → | 008 | Must not be considered at the moment. |
|
|
|