Removing contaminants from the refrigerant circuit |
Flush the refrigerant circuit with R134a (if necessary blow through), if: |
–
| Humidity or dirt has penetrated into the refrigerant circuit (e.g. after an accident). |
–
| The refrigerant has become dark and thick. |
–
| After a compressor replacement there is too much refrigerant oil in the refrigerant circuit. |
–
| The air conditioning compressor must be replaced because of internal damage (e.g. it is too laud, jammed or no output). |
Note Remove contaminants from the refrigerant circuit → Chapter. |
|
|
|