Fill the refrigerant circuit with the A/C service station > < Drain the refrigerant circuit with the A/C service station
Evacuate the refrigerant circuit with the A/C service station
Evacuate the refrigerant circuit with the A/C service station
l  Before the refrigerant circuit is filled with refrigerant, it must be evacuated. In addition, humidity is drawn from the circuit.
l  Depending on the type of the selected A/C service station, variations can occur in the work procedure.
l  The work procedure must always be carried out as described in the operating instructions of the selected A/C service station.
  Caution
t  When evacuating and if vacuum is present in the refrigerant circuit, the engine must not be started.
t  If the engine is started when vacuum is present in the refrigerant circuit, the compressor can be damaged.
Evacuating:
–  Connect the A/C service station to the service connections according to the relevant operating instructions (see refrigerant circuit specifically designed for vehicles) and operate it.
If the vacuum in the system does not remain when evacuating (see instructions), the following must be done:
–  Pour 100 g of refrigerant into the refrigerant circuit, use a leak detector to detect leaks and eliminate them.
–  Evacuate the refrigerant circuit once again.
  Note
Only if the vacuum stays steady, the refrigerant circuit can be filled.
   

Fill the refrigerant circuit with the A/C service station > < Drain the refrigerant circuit with the A/C service station