skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Removing and installing glow plug with flame monitoringQ8 on Thermo Top V > < Plug assignment at control unit for auxiliary heatingJ364 Thermo Top V/VEVO
Removing and installing, checking the temperature sensorG18 and the overheating sensorG189
Removing and installing, checking the temperature sensor -G18- and the overheating sensor -G189-
  Note
Proper functioning can be checked using the → Vehicle diagnostic tester in the function „Targeted fault finding“.
Removing
   
–  Release screw -1- and remove retaining spring -2-.
–  Pull out temperature sensor -G18--3- and overheating sensor -G189--4- using a set of pointed pliers.
Install
Installation is performed in the reverse order, pay attention to the following points:
  Note
t  Pay attention to the correct location of the retaining spring -2-.
t  The sensors cannot be replaced individually.
  S82-0014

Removing and installing glow plug with flame monitoringQ8 on Thermo Top V > < Plug assignment at control unit for auxiliary heatingJ364 Thermo Top V/VEVO