Removing and installing glow plug with flame monitoringQ8 on Thermo Top VEVO
Removing and installing glow plug with flame monitoringQ8 on Thermo Top VEVO
Removing and installing glow plug with flame monitoring -Q8- on Thermo Top VEVO
Removing
–
Remove housing with combustion air blower -V6- → Chapter.
–
Pull out retaining spring -1--arrow-.
–
Remove retaining bracket -2-.
–
Remove glow plug with flame monitoring -Q8- Pos. -3-.
Install
Installation is performed in the reverse order, pay attention to the following points:
Note
t
Observe the fitting position of the retaining spring -1- as well as the retaining bracket -2-.
t
The non-insulated connecting lines to the glow plug must not touch or rest against any other components (risk of short circuit).
t
Proper functioning of the glow plug with flame monitoring -Q8- can be checked using the → Vehicle diagnostic tester in the function „Targeted fault finding“.