When removing the control unit -1-, the cover -2- and the disc spring -5- are removed together. The pressure sensor -4- and the valve -3- are removed separately.
–
Switch off ignition.
–
Separate plug connections -1- and -2- at the top of the control unit.
–
Place catch pan under the final drive.
–
Release screws -arrows-.
Ensure that no parts fall down when removing the control unit.
–
Carefully remove the control unit -A-.
–
Carefully grasp the valve for control of opening degree of coupling -N373--A- at the metal housing -arrow- using pliers and pull out.
–
Pull out pressure sensor -B-.
–
Pull gasket ring for control valve for opening degree of coupling -N373--arrow- out of the housing.