skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Replace coolant temperature senderG62 > < Draining and filling up coolant
Remove and install coolant recirculation pump 2V178
Remove and install coolant recirculation pump 2 -V178-
Special tools and workshop equipment required
t  Hose clamps up to a diameter of 25 mm -MP7-602 (3094)-
t  Pliers for spring strap clamps
Removing
–  Remove the sound dampening system → Body Work; Rep. gr.50.
   
–  Remove right charge air hose.
  N19-10342
–  Release screws -arrows-.
–  Expose coolant hose -3-.
–  Slacken the hose clamp -2- and push the charge air pipe to the right.
  Note
  N15-10493
In order to collect flowing out coolant, place a cloth below the coolant recirculation pump 2 -V178-.
–  Pinch off the coolant hoses with hose clamps up to a diameter of 25 mm -MP7-602-, slacken spring strap clamps -3- and detach the hoses.
–  Unplug connector -2-.
–  Release screws -1- and remove coolant recirculation pump 2 -V178-.
Install
Installation is performed in the reverse order, pay attention to the following points:
  Note
t  Connections as well as charge air pipes and charge air hoses must be free of oil and grease before being installed.
t  Observe the instructions for installing the charge air hoses and tightening torques of the screw clamps → Chapter.
–  Inspect coolant level, top up with coolant if necessary → Chapter.
  A19-10639

Replace coolant temperature senderG62 > < Draining and filling up coolant