Battery recharging or starting by external source on vehicles with „start-stop system“ |
When recharging or starting by external source, pay attention to the following points: |
Do not disconnect the earth strap of the battery when recharging. |
First of all connect to the positive terminals using the charge or jump leads; then connect to the body mass (do not connect to the negative terminal of the battery). |
Note t
| The direct charging (starting aid) of the battery at the negative terminal results in the bypass of the battery monitoring control unit -J367- (then the current flow is not monitored by this control unit). |
t
| The values regarding the battery state, which are stored in the data bus diagnostic interface -J 533- (Gateway), would then no longer correspond to the values of the charged battery. |
t
| This can lead to the failure of the start-stop system. |
|
|
|