01 Technical Data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Mixture preparation system, electronic inj., Gas10 Exhaust system11 Starter-current supply-CC12 Ignition system, glow plug system13 Clutch, control14 Torque converter15 Gearbox mechanics, operation, construction, diff.16 Gearbox, mechanics, gears, shafts, internal operation17 Automatic gearbox, control, assembly, housing18 Automatic gearbox, gears, control19 Final drive, differential, differential lock20 Front suspension, drive shafts21 Rear suspension, drive shaft22 Wheels, tyres. axle align23 ABS, ADR, TCS, EDL, ESP24 Brake, brake mechanics25 Brakes, hydraulics, regulator, servo26 Steering27 Body front28 Body centre, roof, frame29 Body, rear30 Bonnet, flaps, cab, central locking31 Front door, central locking32 Exterior equipment33 Interior equipment34 Trim, noise insulation35 Seat padding, covers36 Air conditioner37 Infotainment38 Windscreen wipe/wash system39 Lights, lamps, switches outside40 Lights, lamps, switches inside, anti-theft system41 Wiring
Skoda Rapid (NA, 2011 on)36 · Air conditioner
36 · Heating & A/C

Check valve for condensation water drain

Make
Skoda
Model
Rapid
Year
NA, 2011 on
Section
Heating, Air conditioning › Check valve for condensation water drain
Air conditionerCheck valve for condensation water drain

Check valve for condensation water drain

Heating, ventilation, air conditioning system · Heating, Air conditioning · Air conditioning system - engine compartment · Rapid from 2011 · Edition 09.2011

S87-0127

Perform the inspection if the floor covering under the air conditioning unit becomes damp when the air conditioning is on.

For an easier access, remove the air filter housing Engine Rep. gr. 23 diesel engines or Engine Rep. gr. 24 petrol engines.

Open perforation of the cap (1) at the bottom of the heat-protection matting (4) and fold up cap.

To guarantee the perfect operation of the valve for condensation water drain, check the following:

  • (5) must not be blocked.
  • (3) of the gasket in the bulkhead (assembly plate) must fit all round in the holder slot (2)(arrows).

The valve for condensation water drain is positioned in the holder (2) and on the air conditioning unit.

  • The heat-protection matting must neither be deformed nor damaged around the valve for condensation water drain.

Note

  • (1) must be flush with the heat-protection matting (4). If the cover (1) is pressed too far inwards, the cap of the valve for condensation water drain (5) may become stuck.