Check valve for condensation water drain
- Make
- Skoda
- Model
- Rapid
- Year
- NA, 2011 on
- Section
- Heating, Air conditioning › Check valve for condensation water drain
Check valve for condensation water drain

Perform the inspection if the floor covering under the air conditioning unit becomes damp when the air conditioning is on.
For an easier access, remove the air filter housing Engine Rep. gr. 23 diesel engines or Engine Rep. gr. 24 petrol engines.
Open perforation of the cap (1) at the bottom of the heat-protection matting (4) and fold up cap.
To guarantee the perfect operation of the valve for condensation water drain, check the following:
- (5) must not be blocked.
- (3) of the gasket in the bulkhead (assembly plate) must fit all round in the holder slot (2)(arrows).
The valve for condensation water drain is positioned in the holder (2) and on the air conditioning unit.
- The heat-protection matting must neither be deformed nor damaged around the valve for condensation water drain.
Note
- (1) must be flush with the heat-protection matting (4). If the cover (1) is pressed too far inwards, the cap of the valve for condensation water drain (5) may become stuck.
Parts & tools for this job For 2011 Skoda Rapid
- PARTEngine gasket setSearch: Skoda Rapid 2011 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.