Repairing the air conditioning system - engine compartment
- Make
- Skoda
- Model
- Superb II
- Year
- 3T, 2008 on
- Section
- Heating, Air conditioning › Repairing the air conditioning system - engine compartment
‹ Prev Checking the function of the fuel shut-off valve N109Next › Climatic, air conditioning system with manual control
Air conditionerRepairing the air conditioning system - engine compartment
Repairing the air conditioning system - engine compartment
Note
- All air conditioning components marked * as well as all refrigerant hoses and refrigerant lines must be repaired in specialist service centres which have suitably trained personnel and are fitted out for working on the refrigerant circuit.
- Air conditioning system with refrigerant R134a Rep. gr. 00 technical data.
- The engine must not be started if the refrigerant lines are not connected to the compressor and the compressor is shut off with plugs (risk of overheating because of the internal refrigerant oil circuit).
- Chapter “Replacing dessicator cartridge / fluid reservoir with dessicator”.
- Electrical System Rep. gr. 27.

- Ambient temperature sensor G17
removing and installing Chapter “removing and installing ambient temperature sensorG17”
check Vehicle diagnostic tester
Fitting location: below the front left bumper at the bumper support - Fluid container with dessicator insert*
removing and installing Chapter “Removing and installing fluid reservoir with dessicator / dessicator cartridge”
Replace fluid reservoir with dessicator / dessicator insert, if… Chapter “Replacing dessicator cartridge / fluid reservoir with dessicator” - Regulating valve for compressor, air conditioning system N280*
Elements of the compressor, do not replace individually Note Depending on the required cooling output the regulating valve receives a PWM signal (500 Hz) from the Climatronic control unitair conditioning control unit J301 or from the Climatronic control unit J255 and regulates the displacement of the compressor via the suction pressure/position of the articulated disc. - Compressor*
different manufacturers and oil capacities: Chapter “Refrigerant R134a”
Removing and installing the refrigerant lines Fig. “Repairing the air conditioning system - engine compartment”
Belt protection for blocked compressor Chapter “Parts for securing the refrigerant circuit”
Removing and installing the compressor Chapter “Removing and installing AC compressor”
Running-in instruction Chapter “Running-in instructions of the AC compressor” - Condenser*
Removing and installing the refrigerant lines Fig. “Repairing the air conditioning system - engine compartment”
Removing and installing the condenser Chapter “Removing and installing the condenser” - High-pressure sender G65
function Chapter “Parts for securing the refrigerant circuit”
removing and installing Fig. “Repairing the air conditioning system - engine compartment”
inspect Vehicle diagnostic tester in the function „Targeted fault finding“ - Pressure relief valve*
Replace O-ring (Electronic Catalogue of Original Parts).
Tightening torque: 10 Nm
function Chapter “Parts for securing the refrigerant circuit”
check Chapter “Inspecting the pressure relief valve on the AC compressor” - Extractor and filling valve*
High-pressure side
for exhausting, filling and measuring
Contents Chapter “Refrigerant R134a”
always screw on cap with gasket
Description, removing and installing Chapter “Extractor, filler and measurement valves for quick couplings of the AC service station on the refrigerant circuit” - Clamp
- Retaining clip
- Exhaust valve*
Low-pressure side
for exhaust and measurement only
always screw on cap with gasket
Description, removing and installing Chapter “Extractor, filler and measurement valves for quick couplings of the AC service station on the refrigerant circuit” - Expansion valve*
removing and installing Chapter “Removing and installing the expansion valve” - Holder for refrigerant lines
- 20 Nm

Note
- After disconnecting, shut off the refrigerant lines and the compressor connections in a suitable manner to protect them from the penetration of ambient humidity.
- Torsion stop with sleeve
- Torsion stop with sleeve
- Electronic Catalogue of Original Parts)
- Electronic Catalogue of Original Parts)

- Electronic Catalogue of Original Parts)
- Torsion stop with sleeve
Note
- After disconnecting, shut off the refrigerant lines and the condenser connection in a suitable manner to protect them from the penetration of ambient humidity.

Switch off the ignition and all electrical components.
Unplug 3-pin connector from high pressure sender G65 (1).
Unscrew high pressure sender.
Tightening torque: 8 Nm
Replace O-ring (Electronic Catalogue of Original Parts), moisten with refrigerant oil and carefully insert.
Note
- The refrigerant circuit remains closed, connection to valve.
- high pressure sender G65(1) can also be fitted according to engine variant on another point close to the condenser.
The function of the high pressure sender G65 can be checked via self-diagnosis of the air conditioning system control unit J301 Vehicle diagnostic tester.
‹ Prev Checking the function of the fuel shut-off valve N109Next › Climatic, air conditioning system with manual control