Generator Dismounting and Remounting

Generator Dismounting and Remounting

Dismounting

1. Disconnect negative (-) cable at battery.
2. Remove air cleaner case and hose.
3. Disconnect generator lead wire ("B" terminal wire) and coupler from generator.
4. Remove water pump and generator drive belt.
5. Remove generator bracket bolt and then remove bracket.
6. Remove generator mounting bolt.
7. Remove generator.

Remounting

1. Install bracket and then tighten generator bracket bolt (3) to specified torque.

Tightening torque
Generator bracket bolt c: 45 Nm (4.5 kg-m, 32.5 lb-ft)

2. Mount generator on the generator bracket.
3. Tighten generator mounting bolt (upper bolt (short) (1), lower bolt (long) (2)).

Tightening torque
Generator mounting upper bolt a: 25 Nm (2.5 kg-m, 18.0 lb-ft) 
Generator mounting lower bolt b: 45 Nm (4.5 kg-m, 32.5 lb-ft)

4. Install water pump and generator drive belt.
5. Connect "B" terminal wire and coupler to generator.

Tightening torque
"B" terminal outer nut d: 7 Nm (0.7 kg-m, 5.0 lb-ft)

6. Install air cleaner case and hose.
7. Connect negative (-) cable at battery.