suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Turn Signal Lamps and/or Indicators Malfunction|Page 17857 > < Turn Signal Lamps and/or Indicators Malfunction|Page 17855
Page 3
background image

^

If the parameter does cycle between the specified values and the left turn signal is inoperative, refer to the Turn Signal Circuit Test.

2. Observe the scan tool Right Turn Signal Switch parameter while using the turn signal/multifunction switch to turn the right turn signal on and off.

The parameter should cycle between Active and Inactive.
^

If the parameter does not cycle between the specified values, refer to Turn Signal/Multifunction Switch Circuit Test.

^

If the parameter does cycle between the specified values and the right turn signal is inoperative, refer to the Turn Signal Circuit Test.

3. Ignition ON, place the turn signal/multifunction switch in the left turn position. The left turn signal indicator on the IPC should cycle ON and OFF.

^

If the indicator is always OFF, replace the IPC.

4. Ignition ON, place the turn signal/multifunction switch in the right turn position. The right turn signal indicator on the IPC should cycle ON and

OFF.
^

If the indicator is always OFF, replace the IPC.

Circuit/System Testing

Turn Signal/Multifunction Switch Circuit Test.

1. Ignition OFF, disconnect the X2 harness connector at the turn signal/multifunction switch.
2. Verify that a test lamp illuminates between the ground circuit terminal B and B+.

^

If the test lamp does not illuminate, test the ground circuit for an open/high resistance.

3. Ignition ON, verify the scan tool Left Turn Signal Switch parameter is Inactive.

^

If not the specified value, test the signal circuit terminal G for a short to ground. If the circuit tests normal, replace the BCM.

4. Verify the scan tool Right Turn Signal Switch parameter is Inactive.

^

If not the specified value, test the signal circuit terminal H for a short to ground. If the circuit tests normal, replace the BCM.

5. Install a 3 A fused jumper wire between the signal circuit terminal G and the ground circuit terminal B. Verify the scan tool Left Turn Signal

Switch parameter is Active.
^

If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM.

6. Install a 3 A fused jumper wire between the signal circuit terminal H and the ground circuit terminal B. Verify the scan tool Right Turn Signal

Switch parameter is Active.
^

If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM.

7. If all circuits test normal, test or replace the turn signal/multifunction switch.

Turn Signal Circuit Test.

1. Ignition OFF, disconnect the X4 harness connector at the BCM.
2. Ignition ON, verify a test lamp illuminates between the following B+ terminals and ground.

^

B+ terminal 1

^

B+ terminal 2

^

B+ terminal 3

^

If the test lamp does not illuminate, test the B+ circuit for an open/high resistance. If the circuit fuse is open, test the B+ circuit and the
respective turn signal circuits for a short to ground.

3. Ignition OFF, disconnect the harness connector at the inoperative turn signal lamp.
4. Test for less than 5.0 ohms of resistance between the ground circuit listed below and ground.

^

Chevrolet front turn signal - terminal 2

^

Pontiac front turn signal - terminal 3

^

Suzuki left front turn signal - terminal G

^

Suzuki right front turn signal - terminal 3

^

Chevrolet and Pontiac rear turn signal - terminal GRND

^

Suzuki rear turn signal - terminal G

^

If greater than the specified range, test the ground circuit for an open/high resistance.

5. Connect a test lamp between the supply voltage circuit listed below and the ground circuit.

^

Chevrolet or Pontiac front turn signal - terminal 1

^

Suzuki left front turn signal - terminal MIN

^

Suzuki right front turn signal - terminal 1

^

Chevrolet and Pontiac rear turn signal - terminal Minor

^

Suzuki rear turn signal - terminal MIN

6. Ignition ON, command the inoperative turn signal ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between

Turn Signal Lamps and/or Indicators Malfunction|Page 17857 > < Turn Signal Lamps and/or Indicators Malfunction|Page 17855