Camry L4-2.4L (2AZ-FXE) Hybrid (2007)
(a) Remove 2 bolts A.
CAUTION: Wear insulated gloves.
NOTICE: Removing bolts A and B in a wrong order may cause the cable and the inverter with converter to break.
(b) While loosening bolt B, disconnect the generator cable.
CAUTION: Wear insulated gloves.
NOTICE:
-
Removing bolts A and B in a wrong order may cause the cable and the inverter with converter to break.
-
Insulate the removed terminals with insulating tape.
-
Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.
(c) Disconnect the wire harness clamp.
13. SEPARATE GENERATOR CABLE
(a) Remove 2 bolts A.
CAUTION: Wear insulated gloves.
NOTICE: Removing bolts A and B in a wrong order may cause the cable and the inverter with converter to break.
(b) While loosening bolt B, disconnect the motor cable.
CAUTION: Wear insulated gloves.
NOTICE:
-
Removing bolts A and B in a wrong order may cause the cable and the inverter with converter to break.
-
Insulate the removed terminals with insulating tape.
-
Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.
(c) Disconnect the wire harness clamp.
14. REMOVE INVERTER RESERVE TANK SUB-ASSEMBLY