(a) Remove 2 bolts A.

CAUTION:  Wear insulated gloves.

NOTICE:  Removing bolts A and B in a wrong order may cause the cable and the inverter with converter to break.

(b) While loosening bolt B, disconnect the generator cable.

CAUTION:  Wear insulated gloves.

NOTICE:
-

Removing bolts A and B in a wrong order may cause the cable and the inverter with converter to break.

-

Insulate the removed terminals with insulating tape.

-

Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.

(c) Disconnect the wire harness clamp.

13. SEPARATE GENERATOR CABLE

(a) Remove 2 bolts A.

CAUTION:  Wear insulated gloves.

NOTICE:  Removing bolts A and B in a wrong order may cause the cable and the inverter with converter to break.

(b) While loosening bolt B, disconnect the motor cable.

CAUTION:  Wear insulated gloves.

NOTICE:
-

Removing bolts A and B in a wrong order may cause the cable and the inverter with converter to break.

-

Insulate the removed terminals with insulating tape.

-

Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.

(c) Disconnect the wire harness clamp.