8. REMOVE NO. 2 ENGINE ROOM SIDE LH COVER
(a) Pull the A part upward to disengage the clip.
(b) Pull the B parts upward by hand to disengage the 2 clips, and remove the No. 2 engine room side LH cover.
9. DRAIN COOLANT (for Inverter) See: Service and Repair/P311 Hybrid Transaxle
10. REMOVE CONNECTOR COVER ASSEMBLY
(a) Remove the 2 bolts and connector cover assembly.
CAUTION:
-
Do not touch the high voltage connectors and terminals for 10 minutes after the service plug grip is removed.
-
Wear insulating gloves.
NOTICE: Do not start the engine with the service plug grip removed because it may cause a malfunction.
11. CHECK TERMINAL VOLTAGE
(a) Using the voltmeter, measure the voltage between the terminals of the 2 phase connectors (N-P).
Standard voltage:
0 V
CAUTION: Wear insulated gloves.
HINT: Use measuring range of DC 750 V or more on the voltmeter.
12. SEPARATE MOTOR CABLE