Page 2
background image

5. Disconnect Discharge Hose

Remove the bolt and disconnect the hose.

Torque:  10 N.m (100 kgf.cm, 7 ft.lbf)

REMOVAL NOTE:  Cap the open fittings immediately to keep moisture or dirt out of the system.

INSTALLATION HINT:  Lubricate a new O-rings with compressor oil and install the tube.

6. Remove Radiator Upper Supports.

7. Remove Condenser.

a. Remove the 2 condenser mounting bolts.
b. Push the radiator toward engine.
c. Push the condenser toward radiator and pull it upward.

INSTALLATION HINT:  If condenser was replaced, add compressor oil to compressor.

Add 40 - 50 cc (1.4 - 1.7 fl.oz.)

Compressor oil:
ND-OIL 8 or equivalent

CONDENSER INSTALLATION

Installation is in the reverse order of removal.