Jumper Installation

- Using a jumper, connect terminals +B and FP of the check connector.
- Reconnect the battery negative (-) cable.
- Turn the ignition switch ON.

NOTICE:Do not start the engine.

Checking Injector Volume

- Connect wire to the injector and battery for 15 seconds, and measure the injection volume with a graduated cylinder. 
- Test each injector two or three times.

Volume:

40 - 50 cm3 (2.4 - 3.1 Cu in.) per 15 sec. 

Difference between each injector:

5 cm3 (0.3 Cu in.) or less

- If the injection volume is not as specified, replace the injector.

Inspect Leakage

- Disconnect wire from the battery and check the fuel leakage from the injector.

Fuel drop:

One drop or less per minute

- Disconnect the battery negative (-) cable.
- Remove jumper wire.