Page 11
background image

a. Connect the high voltage cable of the Generator with the 5 bolts to the w/ converter inverter assembly.

Torque:10 N.m (102 kgf.cm, 7 ft.lbf)

b. Connect the high voltage cable of the Motor with the 5 bolts to the w/ converter inverter assembly.

Torque:10 N.m (102 kgf.cm, 7 ft.lbf)

8. CONNECT ENGINE WIRE NO.4

CAUTION:  Wear insulating gloves.

NOTE:
-

Make sure that the inverter converter is temporarily installed before working on the converter inverter  assembly.

-

Do not allow any foreign objects or waterdrops to enter the w/ converter inverter assembly.

a. Connect the engine wire No.4 with the connector, clamp and grommet to the w/ converter inverter assembly.
b. Connect the engine wire No.4 with the bolt to the w/ converter inverter assembly.

Torque:5.4 N.m (55 kgf.cm, 48 in.lbf)