Matrix FWD L4-1.8L (2ZR-FE) (2010)
(1) Push in the plunger, then check that it returns quickly to its original position.
If necessary, replace the magnet starter switch assembly.
(b) Inspect the resistance of the pull-in coil.
(1) Using an ohmmeter, measure the resistance between terminals 50 and C.
Standard Resistance:
(2) If the result is not as specified, replace the magnet starter switch assembly.
(c) Inspect the resistance of the hold-in coil.
(1) Using an ohmmeter, measure the resistance between terminal 50 and switch body.
Standard Resistance:
(2) If the result is not as specified, replace the magnet starter switch assembly.
3. INSPECT STARTER ARMATURE ASSEMBLY
(a) Inspect the resistance of the commutator.