Tacoma PreRunner Dbl Cab 2WD V6-3.4L (5VZ-FE) (2001)
Condenser HVAC: Service and Repair
REMOVAL
1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM
HINT: At the time of installation, please refer to the following item.
Evacuate air from refrigeration system.
Charge system with refrigerant and inspect for leakage of refrigerant.
Specified amount: 600 ± 50 g (21.16 ± 1.76 oz.)
2. REMOVE THESE PARTS:
a. Radiator grille
b. Horns
c. Hood lock set bolts
d. Center brace
3. REMOVE 2 LIQUID TUBES
a. Remove the 2 bolts and disconnect the liquid tubes from receiver.
Torque: 6.0 N.m (60 kgf.cm, 52 in.lbf)
NOTE: Cap the open fittings immediately to keep moisture or dirt out of the system.
HINT: At the time of installation, please refer to the following item.
Lubricate 2 new O-rings with compressor oil and install the tubes.
b. Loosen the 2 nuts and remove the 2 liquid tubes.
Torque: 14 N.m (140 kgf.cm, 10 ft.lbf)
NOTE: Cap the open fittings immediately to keep moisture or dirt out of the system.
HINT: At the time of installation, please refer to the following item.
Lubricate 2 new O-rings with compressor oil and install the tubes.
4. DISCONNECT DISCHARGE HOSE FROM CONDENSER
a. Remove the piping clamp set bolt.
b. Remove the bolt and disconnect the hose.
Torque: 10 N.m (100 kgf.cm, 7 ft.lbf)
NOTE: Cap the open fitting immediately to keep moisture or dirt out of the system.
HINT: At the time of installation, please refer to the following item. Lubricate a new O-rings with compressor oil and install the tubes.