5. REMOVE CONDENSER

a. Remove the liquid tube clamping bolt.
b. Remove the 2 condenser mounting bolts and pull out the condenser.

HINT:  At the time of installation, please refer to the following item.
If condenser is replaced, add compressor oil to the condenser.

ADD 40 - 50 cc (1.4 - 1.7 ft.oz.)
Compressor oil: ND-OIL 8 or equivalent

INSTALLATION

Installation is in the reverse order of removal.