background image

a. Remove the 4 screws and rectifier holder.

b. Remove the 4 rubber insulators.

5. REMOVE PULLEY

a. Hold SST (A) with a torque wrench, and tighten SST (B) clockwise to the specified torque. 

SST 09820-63010

Torque:  39 N.m (400 kgf.cm, 29 ft.lbf)

b. Check that SST (A) is secured to the rotor shaft.

c. As shown in the illustration, mount SST (C) in a vise, and install the generator with SST (A) and (B) to SST (C).
d. To loosen the pulley nut, turn SST (A) in the direction shown in the illustration.