toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

ABS Actuator|Page 3804 > < ABS Actuator|Page 3802
Page 1
background image

Hydraulic Control Assembly - Antilock Brakes: Testing and Inspection
Hydraulic Brake Booster (w/VSC)

HYDRAULIC BRAKE BOOSTER (w/ VSC) 

ON-VEHICLE INSPECTION  

1. CHECK HYDRAULIC BRAKE BOOSTER FLUID PRESSURE CHANGE

a. Inspect the battery voltage.

Battery voltage: 10 to 14 V 

b. Turn the ignition switch off, and depress the brake pedal more than 20 times.

HINT:  When pressure in the accumulator power supply system is released, reaction force becomes light and stroke becomes longer.

c. Install the brake pedal effort gauge (SST), and bleed air.

SST 09709-29018

d. When booster does not operate:

Depress the brake pedal and check fluid pressure.

At 245 N (25 kgf, 55 ft. lbs.) 

At 343 N (35 kgf, 77 ft. lbs.) 

e. When booster operates:

(1) Turn the ignition switch on and wait until the pump motor has stopped.

HINT:  Pump operating sound can be heard.

(2) Turn the ignition switch off, and depress the brake pedal more than 20 times.

HINT:  When pressure in the accumulator is released, reaction force becomes light and stroke becomes longer.

(3) Repeat (1) and (2) 5 times.
(4) Make sure that the interval between pump start and pump stop is 8 to 14 seconds.
If it takes 14 seconds or more, repeat (3).
(5) Depress the brake pedal and check fluid pressure.

At 49 N (5 kgf, 11 ft. lbs.) 

At 98 N (10 kgf, 22 ft. lbs.) 

At 147 N (15 kgf, 33 ft. lbs.) 

ABS Actuator|Page 3804 > < ABS Actuator|Page 3802