Tank Vent Valve, Remove and Install

  Remove

Detach tank vent valve (1) from air cleaner housing.

Disconnect wiring harness plug (3) from tank vent valve.

Note:   When detaching the tank vent valve hose, ensure that the valve connection is not damaged. Damaged valves must be replaced.

Caution

Damaged valve supports can cause a vehicle fire as a result of leaks.

  Remove

Detach tank vent valve hose (2) from tank vent valve.

Disconnect lead (4) at quick-release fitting with KM-796-A – Seal connection to activated carbon canister.

Object Number: 2414830  Size: DEFAULT

  Install

Install or connect line – quick fitting must noticeably engage.

Connect tank vent valve hose to tank vent valve.

Attach wiring harness plug to tank vent valve.

Fasten tank vent valve to air cleaner housing.