DTC
|
Diagnostic Trouble Code Storage Condition
|
B0165
|
Compartment Temperature Sensor Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 20 (XC42)
|
Concerned Terminals: ECC / SAC: 10, 20 (XC42)
|
Remedy:
|
B0166
|
Compartment Temperature Sensor Circuit High Voltage
|
- Short to voltage or interruption in circuit to control unit terminal 20 (XC42)
|
Concerned Terminals: ECC / SAC: 10, 20 (XC42)
|
Remedy:
|
B0175
|
Air Outlet Temperature Sensor Interior Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 24 (XC43)
|
Concerned Terminals: ECC / SAC: 23, 24 (XC43)
|
Remedy:
|
B0176
|
Air Outlet Temperature Sensor Interior Circuit High Voltage
|
- Short to voltage or interruption in circuit to control unit terminal 24 (XC43)
|
Concerned Terminals: ECC / SAC: 23, 24 (XC43)
|
Remedy:
|
B0180
|
Air Outlet Temperature Sensor Footwell Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 8 (XC43)
|
Concerned Terminals: ECC / SAC: 8, 23 (XC43)
|
Remedy:
|
B0181
|
Air Outlet Temperature Sensor Footwell Circuit High Voltage
|
- Short to voltage or interruption in circuit to control unit terminal 8 (XC43)
|
Concerned Terminals: ECC / SAC: 8, 23 (XC43)
|
Remedy:
|
B0185
|
Solar Sensor Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 21 (XC42)
|
Concerned Terminals: ECC / SAC: 10, 21 (XC42)
|
Remedy:
|
B0186
|
Solar Sensor Circuit High Voltage
|
- Short to voltage or interruption in circuit to control unit terminal 21 (XC42)
|
Concerned Terminals: ECC / SAC: 10, 21 (XC42)
|
Remedy:
|
B0195
|
Blower Motor Circuit Low Voltage
|
- The control unit recognises the malfunction of the circuit via an internal evaluation logic.
|
Concerned Terminals: ECC / SAC: 3, 8 (XC42)
|
Remedy:
|
B0196
|
Blower Motor Circuit High Voltage
|
- The control unit recognises the malfunction of the circuit via an internal evaluation logic.
|
Concerned Terminals: ECC / SAC: 3, 8 (XC42)
|
Remedy:
|
B0225
|
Recirculation Flap Motor Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 1, 17 (XC43)
|
Concerned Terminals: ECC / SAC: 1, 17 (XC43)
|
Remedy:
|
B0226
|
Recirculation Flap Motor Circuit High Voltage
|
- Short to voltage in circuit to control unit terminal 1, 17 (XC43)
|
Concerned Terminals: ECC / SAC: 1, 17 (XC43)
|
Remedy:
|
B0227
|
Recirculation Flap Motor Circuit Open
|
- Circuit interruption to control unit terminal 1, 17 (XC43)
|
Concerned Terminals: ECC / SAC: 1, 17 (XC43)
|
Remedy:
|
B0234
|
Air Distribution Flap Calibration Malfunction
|
- Final stage diagnosis in control unit
(Short circuit to ground or circuit interruption)
|
Concerned Terminals: ECC / SAC: 26 (XC43)
|
Remedy:
|
B0235
|
Air Distribution Flap Motor Low Voltage
|
- Short to ground in circuit to control unit terminal 3, 4, 19, 20 (XC43)
|
Concerned Terminals: ECC / SAC: 3, 4, 7, 19, 20 (XC43)
|
Remedy:
|
B0236
|
Air Distribution Flap Motor High Voltage
|
- Short to voltage in circuit to control unit terminal 3, 4, 19, 20 (XC43)
|
Concerned Terminals: ECC / SAC: 3, 4, 7, 19, 20 (XC43)
|
Remedy:
|
B0237
|
Air Distribution Flap Motor Circuit Open
|
- Circuit interruption to control unit terminal 3, 4, 19, 20 (XC43)
|
Concerned Terminals: ECC / SAC: 3, 4, 7, 19, 20 (XC43)
|
Remedy:
|
B0283
|
Key Stuck
|
- "Back Window Heating" key is stuck
- Above condition must be fulfilled for at least 24 s .
|
Concerned Terminals: -
|
Remedy:
|
B0290
|
Coil Compressor Stroke Control Circuit Low Voltage
|
- The control unit recognises the malfunction of the circuit via an internal evaluation logic.
(Short circuit to ground or circuit interruption)
|
Concerned Terminals: ECC: 16, 31 (XC42)
|
Remedy:
|
B0291
|
Coil Compressor Stroke Control Circuit High Voltage
|
- The control unit recognises the malfunction of the circuit via an internal evaluation logic.
(Short circuit to voltage)
|
Concerned Terminals: ECC: 16, 31 (XC42)
|
Remedy:
|
B0318
|
Key Stuck
|
- The following key is stuck:
Air Conditioning System
- Above condition must be fulfilled for at least 24 s .
|
Concerned Terminals: -
|
Remedy:
|
B0323
|
Key Stuck
|
- "Recirculation" key is stuck
- Above condition must be fulfilled for at least 24 s .
|
Concerned Terminals: -
|
Remedy:
|
B0333
|
Key Stuck
|
- "Defrost" key is stuck
- Above condition must be fulfilled for at least 24 s .
|
Concerned Terminals: -
|
Remedy:
|
B0358
|
Key Stuck
|
- "Auto" key is stuck
- Above condition must be fulfilled for at least 24 s .
|
Concerned Terminals: -
|
Remedy:
|
B0368
|
Key Stuck
|
- "Air Distribution" key is stuck
- Above condition must be fulfilled for at least 24 s .
|
Concerned Terminals: -
|
Remedy:
|
B0410
|
Blending Flap Motor Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 5, 6, 21, 22 (XC43)
|
Concerned Terminals: ECC / SAC: 5, 6, 7, 21, 22 (XC43)
|
Remedy:
|
B0411
|
Blending Flap Motor Circuit High Voltage
|
- Short to voltage in circuit to control unit terminal 5, 6, 21, 22 (XC43)
|
Concerned Terminals: ECC / SAC: 5, 6, 7, 21, 22 (XC43)
|
Remedy:
|
B0412
|
Blending Flap Motor Circuit Open
|
- Circuit interruption to control unit terminal 5, 6, 21, 22 (XC43)
|
Concerned Terminals: ECC / SAC: 5, 6, 7, 21, 22 (XC43)
|
Remedy:
|
B1445
|
Stepper Motors Supply Low Voltage
|
- Short to ground in circuit to control unit terminal 7 (XC43)
|
Concerned Terminals: ECC / SAC: 5, 6, 7, 21, 22 (XC43)
|
Remedy:
|
B2930
|
Anti-Theft Warning System Disable Failed
|
- The ECC has sent a CAN-Bus message to the REC to deactivate the ultrasonic sensor but the REC did not confirm the deactivation.
|
Concerned Terminals: -
|
Remedy:
|
B3843
|
Air Quality Sensor Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 19 (XC42)
|
Concerned Terminals: ECC: 19 (XC42)
|
Remedy:
|
B3843
|
Air Quality Sensor Circuit Open or High Voltage
|
- Short to voltage or interruption in circuit to control unit terminal 19 (XC42)
|
Concerned Terminals: ECC: 19 (XC42)
|
Remedy:
|
P1532
|
Evaporator Temperature Sensor Circuit Low Voltage
|
- Short to ground in circuit to control unit terminal 25 (XC43)
|
Concerned Terminals: ECC: 23, 25 (XC43)
|
Remedy:
|
P1533
|
Evaporator Temperature Sensor Circuit High Voltage
|
- Short to voltage or interruption in circuit to control unit terminal 25 (XC43)
|
Concerned Terminals: ECC: 23, 25 (XC43)
|
Remedy:
|