Test
|
Work Order Description
|
Nominal Value
|
T001
|
Tester Display System Voltage
|
- Ignition ON
- Engine OFF
- All consumers turned off
Note:
This data list parameter is in the data list 1 .
|
11 ... 13.5 V
|
|
greater than 8 V
|
- Engine idling
- Accelerator pedal not actuated
- All consumers turned off
|
12 ... 15 V
|
Concerned Terminals: -
|
|
|
T002
|
Tester Display 'KEY-IN' Status
|
- Ignition ON
- Engine OFF
- All consumers turned off
Note:
This data list parameter is in the data list 1 .
|
Active
|
Concerned Terminals: -
|
|
|
T003
|
Tester Display Ignition Status
|
- Ignition ON
- Engine OFF
- All consumers turned off
Note:
This data list parameter is in the data list 1 .
|
Active
|
Concerned Terminals: -
|
|
|
T004
|
Tester Display Engine Running Status
|
- Ignition ON
- Engine OFF
- All consumers turned off
Note:
This data list parameter is in the data list 1 .
|
Not Running
|
- Engine running at idle speed, operating temperature
|
Run and Idle
|
- Accelerator pedal slightly actuated
|
Run and No Idle
|
Concerned Terminals: -
|
|
|
T005
|
Tester Display Engine Speed
|
- Engine idling
- Accelerator pedal not actuated
- All consumers turned off
Note:
This data list parameter is in the data list 1 .
|
700 ... 1300 RPM.
|
Concerned Terminals: -
|
|
|
T006
|
Tester Display Vehicle Speed
|
- Vehicle travelling (constant speed, approximately 30 km/h (19 mph))
Note:
This data list parameter is in the data list 1 .
|
30 km/h
19 mph
Diagnostic tester display is nearly identical to actual vehicle speed
|
Concerned Terminals: -
|
|
|
T007
|
Tester Display Dimmed Illumination
|
- Ignition ON
- Vehicle illumination OFF
Note:
This data list parameter is in the data list 1 .
|
0 %
|
- Vehicle illumination ON
- Turn dimmer-instrument illumination in both directions until the end is reached.
|
0 ... 100 %
|
Concerned Terminals: -
|
|
|
T008
|
Tester Display Air Quality Sensor
|
- Ignition ON
- Engine OFF
- All consumers turned off
Note:
This data list parameter is in the data list 2 .
|
|
(Electronic Climate Control ECC)
|
8.5 ... 92.5 %
|
(Automatic Climate Control SAC)
|
Not Used
|
Concerned Terminals: ECC: 19 (XC42)
|
|
|
T009
|
Tester Display Evaporator Temperature
|
- Ignition ON
- Engine OFF
- All consumers turned off
Note:
This data list parameter is in the data list 2 .
Important:
If no evaporator temperature sensor is installed, the diagnostic tester displays -40 °C (-40 °F).
|
-39 ... 79 °C
-38 ... 174 °F
0.1 ... 4.9 V
|
Concerned Terminals: ECC: 23, 25 (XC43)
|
|
|
T010
|
Tester Display Add On Heater
|
- Ignition ON
- Engine OFF
- All consumers turned off
Note:
This data list parameter is in the data list 2 .
|
Inactive
|
Concerned Terminals: -
|
|
|
T011
|
Tester Display Blower Fan Setting
|
Note:
This data list parameter is in the data list 3 .
|
-
|
- Air conditioning system is switched on.
- Key " AUTO " pressed briefly
- Blower stage 0 selected
|
0
|
|
7
|
|
0.0
|
|
4.0
|
Concerned Terminals: ECC / SAC: 3, 8 (XC42)
|
|
|
T012
|
Tester Display Blower Feedback
|
- Ignition ON
- Air conditioning system is switched on.
- Key " AUTO " pressed briefly
- Blower stage 0 selected
Note:
This data list parameter is in the data list 3 .
|
|
(Electronic Climate Control ECC)
|
0 V
|
(Automatic Climate Control SAC)
|
Not Used
|
|
|
(Electronic Climate Control ECC)
|
2.5 ... 5.2 V
|
(Automatic Climate Control SAC)
|
Not Used
|
Concerned Terminals: ECC / SAC: 3, 8 (XC42)
|
|
|
T013
|
Tester Display Blending Flap Position
|
Note:
This data list parameter is in the data list 3 .
|
-
|
- Air conditioning system is switched on.
- Key " AUTO " pressed briefly
- Desired temperature HI selected
|
100 %
|
- Desired temperature LO selected
|
0 %
|
- Set desired temperature passenger compartment to HOT
(clock wise to stop)
|
100 %
|
- Set desired temperature passenger compartment to COLD
(counter-clock wise to stop)
|
0 %
|
Concerned Terminals: ECC / SAC: 5, 6, 7, 21, 22 (XC43)
|
|
|
T014
|
Tester Display Air Distribution Flap Position
|
Note:
This data list parameter is in the data list 3 .
|
-
|
- Air conditioning system is switched on.
- Key " AUTO " pressed briefly
|
Auto
|
- Only the symbol "arrow down" is selected in the menu for the air distribution
|
Floor
|
- Only the symbol "arrow right" is selected in the menu for the air distribution
|
Compartment
|
- Only the symbol "arrow up" is selected in the menu for the air distribution
|
Defrost
|
- Set air distribution control to footwell vents
|
16
|
- Set air distribution control to compartment vents
|
4
|
- Set air distribution control to defrost vents
|
8
|
Concerned Terminals: ECC / SAC: 3, 4, 7, 19, 20 (XC43)
|
|
|
T015
|
Tester Display Air Distribution Flap Calibration
|
- Ignition ON
- Engine OFF
- All consumers turned off
Note:
This data list parameter is in the data list 3 .
|
Inactive
|
- Press the keys AUTO and Rear Window Heating simultaneously for longer than 30 s
|
Active
|
- Press the keys "Air Conditioning" and "Rear Window Heating" simultaneously for longer than 30 s
|
Active
Value changing briefly
|
Concerned Terminals: ECC / SAC: 26 (XC43)
|
|
|
T016
|
Tester Display Recirculation Flap Position
|
Note:
This data list parameter is in the data list 3 .
|
-
|
- Air conditioning system is switched on.
- Key " AUTO " pressed briefly
- Circulating air function OFF
|
Fresh
|
- Desired temperature LO selected
- Circulating air function ON
|
Recirculation
|
- Circulating air function OFF
|
Fresh
|
- Set air distribution control to compartment vents
- Circulating air function ON
|
Recirculation
|
Concerned Terminals: ECC / SAC: 1, 17 (XC43)
|
|
|
T017
|
Tester Display Outside Temperature
|
- Ignition ON
- Engine OFF
- All consumers turned off
Note:
This data list parameter is in the data list 4 .
|
0 ... 100 °C
32 ... 212 °F
Diagnostic tester display converges to outside temperature
Condition:
Outside temperature is greater than 0 °C (32 °F)
|
Concerned Terminals: -
|
|
|
T018
|
Tester Display Compartment Temperature
|
- Ignition ON
- Engine OFF
- All consumers turned off
Note:
This data list parameter is in the data list 4 .
|
-39 ... 79 °C
-38 ... 174 °F
0.1 ... 4.9 V
Diagnostic tester display converges to passenger compartment temperature
|
Concerned Terminals: ECC / SAC: 10, 20 (XC42)
|
|
|
T019
|
Tester Display Solar Sensor Intensity
|
- Ignition ON
- Engine OFF
- All consumers turned off
Note:
This data list parameter is in the data list 4 .
|
0.1 ... 4.9 V
|
Concerned Terminals: ECC / SAC: 10, 21 (XC42)
|
|
|
T020
|
Tester Display Footwell Air Outlet Temperature
|
Note:
This data list parameter is in the data list 4 .
|
-
|
- Desired temperature LO selected
- All air vents completely open
- Only the symbol "arrow down" is selected in the menu for the air distribution
- Wait at least 1 min
|
-39 ... 79 °C
-38 ... 174 °F
0.1 ... 4.9 V
|
- Set desired temperature passenger compartment to COLD
(counter-clock wise to stop)
- Set air distribution control to footwell vents
|
-39 ... 79 °C
-38 ... 174 °F
0.1 ... 4.9 V
|
Concerned Terminals: ECC / SAC: 8, 23 (XC43)
|
|
|
T021
|
Tester Display Interior Air Outlet Temperature
|
Note:
This data list parameter is in the data list 4 .
|
-
|
- Desired temperature LO selected
- All air vents completely open
- Only the symbol "arrow right" is selected in the menu for the air distribution
- Wait at least 1 min
|
-39 ... 79 °C
-38 ... 174 °F
0.1 ... 4.9 V
|
- Set desired temperature passenger compartment to COLD
(counter-clock wise to stop)
- Set air distribution control to compartment vents
|
-39 ... 79 °C
-38 ... 174 °F
0.1 ... 4.9 V
|
Concerned Terminals: ECC / SAC: 23, 24 (XC43)
|
|
|
T022
|
Tester Display Engine Coolant Temperature
|
- Engine running at idle speed, operating temperature
- All consumers turned off
Note:
This data list parameter is in the data list 4 .
|
80 ... 121 °C
176 ... 250 °F
|
Concerned Terminals: -
|
|
|
T023
|
Tester Display A/C Pressure
|
- Engine idling
- Accelerator pedal not actuated
- All consumers turned off
Note:
This data list parameter is in the data list 5 .
|
|
(Automatic Climate Control SAC)
|
Not Used
|
(Electronic Climate Control ECC)
|
320 ... 3100 kPa
|
- Engine running at idle speed, operating temperature
- "Air conditioning" is selected in the main menu
|
|
(Automatic Climate Control SAC)
|
Not Used
|
(Electronic Climate Control ECC)
|
Is there a pressure difference of at least 500 kPa ?
|
Concerned Terminals:
(Z 16 XEP) ECM: 3, 4, 34 (XC10)
(Z 18 XE) ECM: 7, 23, 34 (XC4)
(Z 20 LEL) (Z 20 LER) (Z 20 LEH) ECM: 5, 39, 53 (XC8)
(Z 14 XEP) (Z 14 XEL) (Z 12 XEP) ECM: 5, 39, 53 (XC2)
(Z 17 DTL) (Z 17 DTH) ECM: 12, 13, 22 (XC12)
(Z 19 DTH) (Z 19 DT) (Z 19 DTL) ECM: 12, 13, 22 (XC53)
(Z 13 DTH) ECM: 10, 37, 87 (XC20)
(Z 18 XER) ECM: 23, 39, 56 (XC4)
(Z 16 XE1) ECM: 3, 4, 34 (XC10)
(Z 16 LET) (A 16 LET) ECM: 5, 39, 53 (XC98)
(Z 16 XER) ECM: 23, 39, 56 (XC100)
(Z 17 DTJ) (Z 17 DTR) (A 17 DTJ) (A 17 DTR) ECM: 16, 29, 42 (XC96)
(Z 22 YH) ECM: 11, 35, 59 (XC55)
|
|
|
T024
|
Tester Display A/C Request (Air Conditioning)
|
- Engine idling
- Accelerator pedal not actuated
- All consumers turned off
Note:
This data list parameter is in the data list 5 .
|
Inactive
|
- Engine running at idle speed, operating temperature
- Blower stage 3 selected
- "Air conditioning" is not selected in the main menu
Note:
This data list parameter is in the data list 5 .
|
Inactive
|
- "Air conditioning" is selected in the main menu
- Desired temperature LO selected
|
Active
|
- Blower stage 3 selected
- Set desired temperature passenger compartment to COLD
(counter-clock wise to stop)
- Air conditioning system switch ON
|
Active
|
Concerned Terminals: -
|
|
|
T025
|
Tester Display A/C Compressor Stroke Release
|
- Engine running at idle speed, operating temperature
- Air conditioning system is switched on.
- Key " AUTO " pressed briefly
Note:
This data list parameter is in the data list 5 .
|
|
(Air Conditioning Compressor without Clutch)
|
No Limitation
|
(Air Conditioning Compressor with Clutch)
|
Not Used
|
- Accelerator pedal briefly actuated to full load stop
|
|
(Air Conditioning Compressor without Clutch)
|
Fast Shutdown
|
(Air Conditioning Compressor with Clutch)
|
Not Used
|
Concerned Terminals: -
|
|
|
T026
|
Tester Display A/C Compressor Stroke
|
- Ignition ON
- Engine OFF
- All consumers turned off
Note:
This data list parameter is in the data list 5 .
|
|
(Air Conditioning Compressor without Clutch)
|
0 mA
|
(Air Conditioning Compressor with Clutch)
|
Not Used
|
- Engine running at idle speed, operating temperature
- Air conditioning system is switched on.
- Key " AUTO " pressed briefly
|
|
(Air Conditioning Compressor without Clutch)
|
250 ... 800 mA
|
(Air Conditioning Compressor with Clutch)
|
Not Used
|
Concerned Terminals: ECC: 16, 31 (XC42)
|
|
|
T027
|
Tester Display A/C Compressor Feedback
|
- Ignition ON
- Engine OFF
- All consumers turned off
Note:
This data list parameter is in the data list 5 .
|
|
(Air Conditioning Compressor without Clutch)
|
0 mA
|
(Air Conditioning Compressor with Clutch)
|
Not Used
|
- Engine running at idle speed, operating temperature
- Air conditioning system is switched on.
- Key " AUTO " pressed briefly
|
|
(Air Conditioning Compressor without Clutch)
|
250 ... 800 mA
|
(Air Conditioning Compressor with Clutch)
|
Not Used
|
Concerned Terminals: ECC: 16, 31 (XC42)
|
|
|
T028
|
Tester Display Rear Window Heater Request
|
- Engine idling
- Rear window heating OFF
Note:
This data list parameter is in the data list 5 .
|
Inactive
|
|
Active
Value changing briefly
|
Concerned Terminals: REC: 4 (XR2)
|
|
|
T029
|
Tester Display Rear Window Heater Status
|
- Engine idling
- Rear window heating OFF
Note:
This data list parameter is in the data list 5 .
|
Inactive
|
|
Active
|
Concerned Terminals: REC: 4 (XR2)
|
|
|