vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

B-003 Diagnostic System Check > < B-001 DIAGNOSTIC TROUBLE CODE

B-002 - DATA LIST

Test

Work Order Description

Nominal Value

T001 Tester Display System Voltage
  • Ignition ON
  • Engine OFF
  • All consumers turned off

Note:

This data list parameter is in the data list 1 .

11 ... 13.5 V
  • Engine starting
greater than 8 V
  • Engine idling
  • Accelerator pedal not actuated
  • All consumers turned off
12 ... 15 V
Concerned Terminals:
-
 
Yes: No:
T002 Tester Display 'KEY-IN' Status
  • Ignition ON
  • Engine OFF
  • All consumers turned off

Note:

This data list parameter is in the data list 1 .

Active
Concerned Terminals:
-
 
Yes: No:
T003 Tester Display Ignition Status
  • Ignition ON
  • Engine OFF
  • All consumers turned off

Note:

This data list parameter is in the data list 1 .

Active
Concerned Terminals:
-
 
Yes: No:
T004 Tester Display Engine Running Status
  • Ignition ON
  • Engine OFF
  • All consumers turned off

Note:

This data list parameter is in the data list 1 .

Not Running
  • Engine running at idle speed, operating temperature
Run and Idle
  • Accelerator pedal slightly actuated
Run and No Idle
Concerned Terminals:
-
 
Yes: No:
T005 Tester Display Engine Speed
  • Engine idling
  • Accelerator pedal not actuated
  • All consumers turned off

Note:

This data list parameter is in the data list 1 .

700 ... 1300 RPM.
Concerned Terminals:
-
 
Yes: No:
T006 Tester Display Vehicle Speed
  • Vehicle travelling (constant speed, approximately 30 km/h (19 mph))

Note:

This data list parameter is in the data list 1 .

30 km/h
19 mph
Diagnostic tester display is nearly identical to actual vehicle speed
Concerned Terminals:
-
 
Yes: No:
T007 Tester Display Dimmed Illumination
  • Ignition ON
  • Vehicle illumination OFF

Note:

This data list parameter is in the data list 1 .

0 %
  • Vehicle illumination ON
  • Turn dimmer-instrument illumination in both directions until the end is reached.
0 ... 100 %
Concerned Terminals:
-
 
Yes: No:
T008 Tester Display Air Quality Sensor
  • Ignition ON
  • Engine OFF
  • All consumers turned off

Note:

This data list parameter is in the data list 2 .

 
(Electronic Climate Control ECC)
8.5 ... 92.5 %
(Automatic Climate Control SAC)
Not Used
Concerned Terminals:
ECC: 19 (XC42)
 
Yes: No:
T009 Tester Display Evaporator Temperature
  • Ignition ON
  • Engine OFF
  • All consumers turned off

Note:

This data list parameter is in the data list 2 .

Important:

If no evaporator temperature sensor is installed, the diagnostic tester displays -40 °C (-40 °F).

-39 ... 79 °C
-38 ... 174 °F
0.1 ... 4.9 V
Concerned Terminals:
ECC: 23, 25 (XC43)
 
Yes: No:
T010 Tester Display Add On Heater
  • Ignition ON
  • Engine OFF
  • All consumers turned off

Note:

This data list parameter is in the data list 2 .

Inactive
Concerned Terminals:
-
 
Yes: No:
T011 Tester Display Blower Fan Setting
  • Ignition ON

Note:

This data list parameter is in the data list 3 .

-
  • Air conditioning system is switched on.
  • Key " AUTO " pressed briefly
  • Blower stage 0 selected
0
  • Blower stage 7 selected
7
  • Blower stage 0 selected
0.0
  • Blower stage 4 selected
4.0
Concerned Terminals:
ECC / SAC: 3, 8 (XC42)
 
Yes: No:
T012 Tester Display Blower Feedback
  • Ignition ON
  • Air conditioning system is switched on.
  • Key " AUTO " pressed briefly
  • Blower stage 0 selected

Note:

This data list parameter is in the data list 3 .

 
(Electronic Climate Control ECC)
0 V
(Automatic Climate Control SAC)
Not Used
  • Blower stage 7 selected
 
(Electronic Climate Control ECC)
2.5 ... 5.2 V
(Automatic Climate Control SAC)
Not Used
Concerned Terminals:
ECC / SAC: 3, 8 (XC42)
 
Yes: No:
T013 Tester Display Blending Flap Position
  • Ignition ON

Note:

This data list parameter is in the data list 3 .

-
  • Air conditioning system is switched on.
  • Key " AUTO " pressed briefly
  • Desired temperature HI selected
100 %
  • Desired temperature LO selected
0 %
  • Set desired temperature passenger compartment to HOT
    (clock wise to stop)
100 %
  • Set desired temperature passenger compartment to COLD
    (counter-clock wise to stop)
0 %
Concerned Terminals:
ECC / SAC: 5, 6, 7, 21, 22 (XC43)
 
Yes: No:
T014 Tester Display Air Distribution Flap Position
  • Ignition ON

Note:

This data list parameter is in the data list 3 .

-
  • Air conditioning system is switched on.
  • Key " AUTO " pressed briefly
Auto
  • Only the symbol "arrow down" is selected in the menu for the air distribution
Floor
  • Only the symbol "arrow right" is selected in the menu for the air distribution
Compartment
  • Only the symbol "arrow up" is selected in the menu for the air distribution
Defrost
  • Set air distribution control to footwell vents
16
  • Set air distribution control to compartment vents
4
  • Set air distribution control to defrost vents
8
Concerned Terminals:
ECC / SAC: 3, 4, 7, 19, 20 (XC43)
 
Yes: No:
T015 Tester Display Air Distribution Flap Calibration
  • Ignition ON
  • Engine OFF
  • All consumers turned off

Note:

This data list parameter is in the data list 3 .

Inactive
  • Press the keys AUTO and Rear Window Heating simultaneously for longer than 30 s
Active
  • Press the keys "Air Conditioning" and "Rear Window Heating" simultaneously for longer than 30 s
Active
Value changing briefly
Concerned Terminals:
ECC / SAC: 26 (XC43)
 
Yes: No:
T016 Tester Display Recirculation Flap Position
  • Ignition ON

Note:

This data list parameter is in the data list 3 .

-
  • Air conditioning system is switched on.
  • Key " AUTO " pressed briefly
  • Circulating air function OFF
Fresh
  • Desired temperature LO selected
  • Circulating air function ON
Recirculation
  • Circulating air function OFF
Fresh
  • Set air distribution control to compartment vents
  • Circulating air function ON
Recirculation
Concerned Terminals:
ECC / SAC: 1, 17 (XC43)
 
Yes: No:
T017 Tester Display Outside Temperature
  • Ignition ON
  • Engine OFF
  • All consumers turned off

Note:

This data list parameter is in the data list 4 .

0 ... 100 °C
32 ... 212 °F
Diagnostic tester display converges to outside temperature
Condition:
Outside temperature is greater than 0 °C (32 °F)
Concerned Terminals:
-
 
Yes: No:
T018 Tester Display Compartment Temperature
  • Ignition ON
  • Engine OFF
  • All consumers turned off

Note:

This data list parameter is in the data list 4 .

-39 ... 79 °C
-38 ... 174 °F
0.1 ... 4.9 V
Diagnostic tester display converges to passenger compartment temperature
Concerned Terminals:
ECC / SAC: 10, 20 (XC42)
 
Yes: No:
T019 Tester Display Solar Sensor Intensity
  • Ignition ON
  • Engine OFF
  • All consumers turned off

Note:

This data list parameter is in the data list 4 .

0.1 ... 4.9 V
Concerned Terminals:
ECC / SAC: 10, 21 (XC42)
 
Yes: No:
T020 Tester Display Footwell Air Outlet Temperature
  • Ignition ON

Note:

This data list parameter is in the data list 4 .

-
  • Desired temperature LO selected
  • All air vents completely open
  • Only the symbol "arrow down" is selected in the menu for the air distribution
  • Wait at least 1 min
-39 ... 79 °C
-38 ... 174 °F
0.1 ... 4.9 V
  • Set desired temperature passenger compartment to COLD
    (counter-clock wise to stop)
  • Set air distribution control to footwell vents
-39 ... 79 °C
-38 ... 174 °F
0.1 ... 4.9 V
Concerned Terminals:
ECC / SAC: 8, 23 (XC43)
 
Yes: No:
T021 Tester Display Interior Air Outlet Temperature
  • Ignition ON

Note:

This data list parameter is in the data list 4 .

-
  • Desired temperature LO selected
  • All air vents completely open
  • Only the symbol "arrow right" is selected in the menu for the air distribution
  • Wait at least 1 min
-39 ... 79 °C
-38 ... 174 °F
0.1 ... 4.9 V
  • Set desired temperature passenger compartment to COLD
    (counter-clock wise to stop)
  • Set air distribution control to compartment vents
-39 ... 79 °C
-38 ... 174 °F
0.1 ... 4.9 V
Concerned Terminals:
ECC / SAC: 23, 24 (XC43)
 
Yes: No:
T022 Tester Display Engine Coolant Temperature
  • Engine running at idle speed, operating temperature
  • All consumers turned off

Note:

This data list parameter is in the data list 4 .

80 ... 121 °C
176 ... 250 °F
Concerned Terminals:
-
 
Yes: No:
T023 Tester Display A/C Pressure
  • Engine idling
  • Accelerator pedal not actuated
  • All consumers turned off

Note:

This data list parameter is in the data list 5 .

 
(Automatic Climate Control SAC)
Not Used
(Electronic Climate Control ECC)
320 ... 3100 kPa
  • Engine running at idle speed, operating temperature
  • "Air conditioning" is selected in the main menu
 
(Automatic Climate Control SAC)
Not Used
(Electronic Climate Control ECC)
Is there a pressure difference of at least 500 kPa ?
Concerned Terminals:
(Z 16 XEP)
ECM: 3, 4, 34 (XC10)
(Z 18 XE)
ECM: 7, 23, 34 (XC4)
(Z 20 LEL) (Z 20 LER) (Z 20 LEH)
ECM: 5, 39, 53 (XC8)
(Z 14 XEP) (Z 14 XEL) (Z 12 XEP)
ECM: 5, 39, 53 (XC2)
(Z 17 DTL) (Z 17 DTH)
ECM: 12, 13, 22 (XC12)
(Z 19 DTH) (Z 19 DT) (Z 19 DTL)
ECM: 12, 13, 22 (XC53)
(Z 13 DTH)
ECM: 10, 37, 87 (XC20)
(Z 18 XER)
ECM: 23, 39, 56 (XC4)
(Z 16 XE1)
ECM: 3, 4, 34 (XC10)
(Z 16 LET) (A 16 LET)
ECM: 5, 39, 53 (XC98)
(Z 16 XER)
ECM: 23, 39, 56 (XC100)
(Z 17 DTJ) (Z 17 DTR) (A 17 DTJ) (A 17 DTR)
ECM: 16, 29, 42 (XC96)
(Z 22 YH)
ECM: 11, 35, 59 (XC55)
 
Yes: No:
T024 Tester Display A/C Request (Air Conditioning)
  • Engine idling
  • Accelerator pedal not actuated
  • All consumers turned off

Note:

This data list parameter is in the data list 5 .

Inactive
  • Engine running at idle speed, operating temperature
  • Blower stage 3 selected
  • "Air conditioning" is not selected in the main menu

Note:

This data list parameter is in the data list 5 .

Inactive
  • "Air conditioning" is selected in the main menu
  • Desired temperature LO selected
Active
  • Blower stage 3 selected
  • Set desired temperature passenger compartment to COLD
    (counter-clock wise to stop)
  • Air conditioning system switch ON
Active
Concerned Terminals:
-
 
Yes: No:
T025 Tester Display A/C Compressor Stroke Release
  • Engine running at idle speed, operating temperature
  • Air conditioning system is switched on.
  • Key " AUTO " pressed briefly

Note:

This data list parameter is in the data list 5 .

 
(Air Conditioning Compressor without Clutch)
No Limitation
(Air Conditioning Compressor with Clutch)
Not Used
  • Accelerator pedal briefly actuated to full load stop
 
(Air Conditioning Compressor without Clutch)
Fast Shutdown
(Air Conditioning Compressor with Clutch)
Not Used
Concerned Terminals:
-
 
Yes: No:
T026 Tester Display A/C Compressor Stroke
  • Ignition ON
  • Engine OFF
  • All consumers turned off

Note:

This data list parameter is in the data list 5 .

 
(Air Conditioning Compressor without Clutch)
0 mA
(Air Conditioning Compressor with Clutch)
Not Used
  • Engine running at idle speed, operating temperature
  • Air conditioning system is switched on.
  • Key " AUTO " pressed briefly
 
(Air Conditioning Compressor without Clutch)
250 ... 800 mA
(Air Conditioning Compressor with Clutch)
Not Used
Concerned Terminals:
ECC: 16, 31 (XC42)
 
Yes: No:
T027 Tester Display A/C Compressor Feedback
  • Ignition ON
  • Engine OFF
  • All consumers turned off

Note:

This data list parameter is in the data list 5 .

 
(Air Conditioning Compressor without Clutch)
0 mA
(Air Conditioning Compressor with Clutch)
Not Used
  • Engine running at idle speed, operating temperature
  • Air conditioning system is switched on.
  • Key " AUTO " pressed briefly
 
(Air Conditioning Compressor without Clutch)
250 ... 800 mA
(Air Conditioning Compressor with Clutch)
Not Used
Concerned Terminals:
ECC: 16, 31 (XC42)
 
Yes: No:
T028 Tester Display Rear Window Heater Request
  • Engine idling
  • Rear window heating OFF

Note:

This data list parameter is in the data list 5 .

Inactive
  • Rear window heating ON
Active
Value changing briefly
Concerned Terminals:
REC: 4 (XR2)
 
Yes: No:
T029 Tester Display Rear Window Heater Status
  • Engine idling
  • Rear window heating OFF

Note:

This data list parameter is in the data list 5 .

Inactive
  • Rear window heating ON
Active
Concerned Terminals:
REC: 4 (XR2)
 
Yes: No:





B-003 Diagnostic System Check > < B-001 DIAGNOSTIC TROUBLE CODE