Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Short to Voltage/Ground/Interruption of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
B1_A14 Sensor - Outlet Temperature Footwell
- Ignition ON
- Measure voltage between the following terminals:
B1_A14 Sensor - Outlet Temperature Footwell Wiring harness connector (wiring harness side) terminal A & Ground
|
4.8 ... 5.2 V
|
|
|
T002
|
Check: Component
|
- Select the following Functional System on the diagnostic tester:
ECC/SAC (Electronic Climate Control)
- Diagnostic Tester Data List Parameter
Footwell Air Outlet Temperature
|
greater than 4.8 V
|
|
|
T003
|
Check: Short to Voltage/Interruption of Signal Circuit
|
- Ignition OFF
- Connect fused jumper wire to:
B1_A14 Sensor - Outlet Temperature Footwell Wiring harness connector (wiring harness side) terminal A & B1_A14 Sensor - Outlet Temperature Footwell Wiring harness connector (wiring harness side) terminal B
- Ignition ON
- Diagnostic Tester Data List Parameter
Footwell Air Outlet Temperature
|
less than 0.3 V
|
|
|
T004
|
Check: Short to Voltage/Ground/Interruption of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
B1_A14 Sensor - Outlet Temperature Footwell
- Ignition ON
- Measure voltage between the following terminals:
B1_A14 Sensor - Outlet Temperature Footwell Wiring harness connector (wiring harness side) terminal A & Ground
|
greater than 5.2 V
|
|
|